In order to provide you with a straightforward, easy-to-use solution for the detection of volatile organic compounds (VOCs) in Fire and Arson Investigation applications, ION Science has developed the Fire Investigation Kit with Tiger or Tiger LT photoionization detector (PID).
It is an element of the fire investigation in cases of suspected arson to prove that there was no other source of the fire. Hydrocarbon chemicals such as petrol, alkanes, and cycloalkanes can be detected with the Fire Investigation Kit. It is the job of fire investigators to look for every form of accelerant in the event of a fire, from grill lighters and lighter fuel to liquid glue and cleaning solvents.
Features:
- ATEX Zone 0
- IECEx
- 10.6 eV Krypton PID lamp (standard)
- 10.0 eV and 11.7 eV lamp optional
- Li-Ion battery
- Integrated Flashlight
- Bump Test Pen
- AA Tiger battery pack
- Charging cradle
- Travel charger adaptor
- PTFE filters
- IP65 (heavy rain)
Specifications:
TIGER LT SPECIFICATIONS | |
Minimum resolution* | 0.1 ppm |
Maximum reading | 5,000 ppm |
Response time | T90 < 2 seconds |
Accuracy* | 5% display reading one digit |
Linearity* | 5% display reading one digit |
Intrinsically safe approvals | II 1G Ex ia IIC T4 Ga |
Tamb = - 15 0C ≤Ta ≤+45 0C (with lithium ion battery pack) | |
Tamb = - 15 0C ≤Ta ≤+40 0C (with alkaline battery pack) | |
ITS09ATEX26890X IECEx ITS 10.0036X | |
3193491 conforms to UL Std. 913, 61010-1 & | |
Certified to CAN/CSA Std. C22.2 No. 61010-1 | |
Battery life | Li-ion: life up to 24 hours continual use |
Lamps | 10.6 eV Krypton PID lamp (standard.) |
Data logging | Push-to-log, 128 zones, 80,000 data points |
Calibration | Standard calibration 100 ppm isobutylene |
Custom calibration capability | |
Alarm | Flashing LED and 95 dBA at 300mm (12”) audible sounder |
Selectable vibrating alarm | |
Flow rate | 220 ml/min in ambient conditions (with blocked flow alarm) |
Temperature | Operating: -20 to 60 0C, -4 to 140 0F (non-Intrinsically Safe) |
Humidity: 0-99% RH (non condensing) | |
Protection | Designed to IP65 (heavy rain) |
1180 | |
EMC tested to EN61326- 1:2006, EN50270:2006 & CFR 47:2008 Class A | |
Weight & dimensions | Instrument (with probe) |
Width: 91.4 x Height: 370 x | |
Depth: 61 mm (3.59 x 14.56 x 2.4”) | |
Instrument weight 0.75 kg |
TIGER SPECIFICATIONS | |
Minimum resolution* | 1 ppb or 0.001 mg/m3 |
Maximum reading | 20,000 ppm or 20,000 mg/ m3 (gas dependent) |
Response time | T90 < 2 seconds |
Accuracy* | 5% display reading one digit |
Linearity* | 5% display reading one digit |
Intrinsically safe approvals | II 1G Ex ia IIC T4 Ga |
Tamb = - 15 0C ≤Ta ≤+45 0C (with lithium ion battery pack) | |
Tamb = - 15 0C ≤Ta ≤+45 0C (with alkaline battery pack) | |
ITS09ATEX26890X IECEx ITS 10.0036X | |
3193491 conforms to UL Std. 913, 61010-1 & | |
Certified to CAN/CSA Std. C22.2 No. 61010-1 | |
Battery life | Li-ion: life up to 24 hours continual use |
Alkaline: (Duracell Procell MN 1500) life up to 8.5 hours continual use | |
Lamps | 10.6 eV Krypton PID lamp (standard.) 10.0 eV and 11.7 eV lamps available |
Data logging | Including date / time: 120,000 points |
Communication | Direct USB 1.1 connection |
Alarm | Flashing LED and 95 dBA at 300mm (12”) audible sounder |
Selectable vibrating alarm | |
Pre-programmed TWA and STEL* | |
Pre-programmed with over 700 gases* | |
Flow rate | 220 ml/min in ambient conditions (with blocked flow alarm) |
Temperature | Operating: -20 to 60 0C, -4 to 140 0F (non Intrinsically Safe) |
Humidity: 0-99% RH (non condensing) | |
Protection | Designed to IP65 (heavy rain) |
1180 | |
EMC tested to EN61326-1:2006, EN50270:2006 & CFR 47:2008 Class A | |
Weight & dimensions | Instrument with probe |
Width: 340 x Height: 90 x Depth: 60 mm (13.4 x 3.6 x 2.4”) | |
Standard case | |
367 x 89 x 90 mm (14.45 x 3.54 x 2.36”) | |
Instrument weight 0.72 kg (1.56lb) | |
Packed weight: 5 .5kg (12lb) |
Certifications:
- ATEX Certificate
- IECEx Certificate
- Brochure
- Brochure Catalog
- Technial Application Article
- Technical Bulletin
What others are saying
There are no contributions yet.