Your cart is empty.

This product is currently unavailable. Our team can help you find a suitable alternative or advise on lead times.
Ion Science Tiger’s ATEX Zone 0 certified handheld VOC gas detector is intrinsically safe. In agreement with IECEx. Detection of Volatile Organic Compound gases (VOC’s) down to ppb levels is possible with the Tiger handheld VOC detector. In addition to being very resistant to moisture and contamination, it is capable of rapidly and accurately detecting volatile organic compounds (VOCs). It has a lithium-ion battery that lasts up to 24 hours of continuous use, a backlit LCD screen, a tactile keyboard, user-friendly firmware, dual-color status LEDs, and an alarm that vibrates at 95 dB. IP65.
| Country of Origin | United Kingdom (GB) |
| ATEX Rating | Zone 0 |
| IECEx Certified | Yes |
Because it has a minimum sensitivity of 0.001 parts per billion (ppb), the Tiger handheld VOC gas detector has the greatest measurement range of any other VOC detector now on the market. The two-second response speed of this portable, handheld detector is the fastest on the market, and it is just as quick to clear. Tiger is a battery replacement system that may be used safely in dangerous conditions. Rechargeable Li-ion batteries can be used for up to 24 hours. The instrument can be fully charged in 6.5 hours, while it may be used for 8 hours with a 1.5-hour battery charge.
In addition to the low-cost Tiger LT, the Tiger Select detects all aromatic chemicals, including benzene, and is available in the Tiger line of handheld VOC gas detectors.
| Minimum resolution* | 1 ppb or 0.001 mg/m3 |
| Maximum reading** | 20,000 ppm or 20,000 mg/m3 (gas dependent) |
| Response time | T90 < 2 seconds |
| Accuracy* | 5% display reading one digit |
| Linearity* | 5% display reading one digit |
| Intrinsically safe approvals | II 1G Ex ia IIC T4 Ga |
| Tamb = - 15 0C ≤Ta ≤+45 0C (with lithium ion battery pack) | |
| Tamb = - 15 0C ≤Ta ≤+45 0C (with alkaline battery pack) | |
| ITS09ATEX26890X IECEx ITS 10.0036X | |
| 3193491 conforms to UL Std. 913, 61010-1 & | |
| Certified to CAN/CSA Std. C22.2 No. 61010-1 | |
| Battery life | Li-ion: life up to 24 hours continual use |
| Alkaline: (Duracell Procell MN 1500) life up to 8.5 hours continual use | |
| Lamps | 10.6 eV Krypton PID lamp (standard.) 10.0 eV and 11.7 eV lamps available |
| Data logging* | Including date / time: 120,000 points |
| Communication | Direct USB 1.1 connection |
| Alarm | Flashing LED and 95 dBA at 300mm (12”) audible sounder |
| Selectable vibrating alarm | |
| Pre-programmed TWA and STEL* | |
| Pre-programmed with over 700 gases* | |
| Flow rate | 220 ml/min in ambient conditions (with blocked flow alarm) |
| Temperature | Operating: -20 to 60 0C, -4 to 140 0F (non Intrinsically Safe) |
| Humidity: 0-99% RH (non condensing) | |
| Protection | Designed to IP65 (heavy rain) |
| 1180 | |
| EMC tested to EN61326-1:2006, EN50270:2006 & CFR 47:2008 Class A | |
| Weight & dimensions | Instrument with probe |
| Width: 340 x Height: 90 x Depth: 60 mm (13.4 x 3.6 x 2.4”) | |
| Standard case | |
| 367 x 89 x 90 mm (14.45 x 3.54 x 2.36”) | |
| Instrument weight 0.72 kg (1.56lb) | |
| Packed weight: 5 .5kg (12lb) | |
| * Model and gas dependent | |
| ** Maximum reading is achieved with certain analytes such as ethanol |