XP Climate 36,000 BTU Explosion Proof Mini Split Heat Pump – C1D2 Groups B, C, D – Indoor Unit Hazardous Rated

SKU: EP-MS36HP-1-2-B-(I)-216-1Z

The XP Climate EP-MS36HP-1-2-B-(I)-216-1Z is a 36,000 BTU explosion proof mini split heat pump designed for Class I Division 2 Groups B, C, and D hazardous locations. This single-zone HVAC system features a hazardous-rated indoor evaporator for use in classified environments, delivering 33,600 BTU cooling and 34,000 BTU heating capacity for industrial climate control in oil & gas, chemical, refinery, and industrial facilities.

⚠️ Important Installation Note: This model includes a general-purpose outdoor condenser (non-certified) that must be installed in a non-hazardous area only. The indoor evaporator is the hazardous-rated component certified for Class I Division 2 Groups B, C, and D.

Weight 350 lbs
Dimensions 60 × 36 × 48 in
Country of Origin 🇺🇸 United States (US)

$18,10000

Shipping Time

8–10 weeks

Need faster options? Contact our Hazardous Areas Experts now for quick alternatives!

Found It Cheaper?

We Match It!
Price Match Guarantee

Need Help?

Speak with a Hazardous Area expert now

Description

XP Climate 36,000 BTU Explosion Proof Mini Split Heat Pump – C1D2 Groups B, C, D – Indoor Unit Hazardous Rated

The XP Climate EP-MS36HP-1-2-B-(I)-216-1Z Explosion Proof Mini Split Heat Pump is a hazardous location HVAC solution designed for facilities where the indoor environment requires Class I Division 2 hazardous area protection, while the outdoor condenser can safely remain in a non-hazardous location. Rated for Class I Division 2 Groups B, C, and D, this industrial mini split system is ideal for oil & gas facilities, refineries, petrochemical plants, compressor buildings, MCC rooms, electrical control rooms, analyzer shelters, offshore facilities, and industrial processing environments requiring certified climate control.

Engineered for demanding industrial applications, this single-zone mini split heat pump delivers 33,600 BTU cooling capacity and 34,000 BTU heating capacity while operating on 208–230V single-phase power. The indoor evaporator section is hazardous location certified for Class I Division 2 Groups B, C, and D, while the outdoor condenser is a general-purpose unit designed for installation outside hazardous areas. Featuring an explosion proof handheld thermostat, automatic defrost functionality, motor overload protection, and factory operational testing for NEC compliance, the EP-MS36HP-1-2-B-(I)-216-1Z provides dependable heating and cooling performance for industrial environments.

Key Features:

Class I Division 2 Groups B, C, D certified indoor evaporator for hazardous locations
Indoor hazardous rated / outdoor general-purpose configuration for facilities where only the interior space requires explosion proof protection
33,600 BTU cooling capacity for reliable industrial climate control
34,000 BTU heating capacity for year-round temperature management
Explosion proof handheld thermostat included for safe temperature control inside hazardous locations
208–230V single phase operation designed for industrial power systems
Automatic defrost system for dependable performance in changing environments
Factory tested for NEC compliance with Certificate of Conformance included

📦 Package Options:

🔹 Indoor Hazardous Rated Version: Certified Class I Division 2 Groups B, C, D indoor evaporator with general-purpose outdoor condenser designed for non-hazardous installation areas.
🔹 Fully Hazardous Rated Version Available: Contact us for systems with both indoor and outdoor sections certified for hazardous locations.

XP Climate EP-MS36HP-1-2-B-(I)-216-1Z Technical Specifications:

FeatureDetails
ManufacturerXP Climate Control
ModelEP-MS36HP-1-2-B-(I)-216-1Z
Product TypeExplosion Proof Mini Split Heat Pump
System TypeSingle Zone
Cooling Capacity33,600 BTU
Heating Capacity34,000 BTU
Power Supply208–230V / 1Ph / 60Hz
Refrigerant TypeR-32
Indoor Unit CertificationClass I Division 2 Groups B, C, D
Outdoor Unit TypeGeneral Purpose (Non-Hazardous Area Only)
Hazardous Area ClassificationClass I Division 2
Gas GroupsGroups B, C, D
Compressor TypeRotary
Condenser TypeAluminum Fin / Copper Tube
Defrost MethodAutomatic
Protection FeaturesExplosion proof motor, motor overload protection, condenser fan overload protection, low pressure switch, high pressure switch
Thermostat IncludedExplosion Proof Handheld Thermostat
Electrical ComponentsUL & CSA Approved
Testing & ComplianceFactory Tested for Operational Performance and NEC Compliance
Documentation IncludedOwner & Maintenance Manuals + Certificate of Conformance
Recommended InstallationIndoor hazardous area / outdoor non-hazardous area

Certifications & Compliance:

🔗 Class I Division 2 Groups B, C, D – Indoor evaporator certified for hazardous gas and vapor locations
🔗 Group B Hydrogen Compatible – Suitable for hydrogen-related industrial applications
🔗 NEC Compliant – Factory tested for operational performance and National Electrical Code compliance
🔗 Certificate of Conformance Included – Factory-issued documentation provided
🔗 General Purpose Outdoor Condenser – Designed for installation outside hazardous locations only

Applications of XP Climate EP-MS36HP-1-2-B-(I)-216-1Z:

🔹 Oil & Gas Facilities
🔹 Refineries
🔹 Petrochemical Plants
🔹 Battery Charging Rooms
🔹 Compressor Buildings
🔹 Electrical Control Rooms
🔹 MCC Rooms
🔹 Analyzer Shelters
🔹 Offshore Platforms
🔹 Industrial Manufacturing Facilities

What’s in the Box?

📦 1x XP Climate EP-MS36HP-1-2-B-(I)-216-1Z Mini Split Heat Pump
📦 1x Hazardous Location Indoor Evaporator Unit
📦 1x General Purpose Outdoor Condenser Unit
📦 1x Explosion Proof Handheld Thermostat
📦 1x Owner & Maintenance Documentation Kit
📦 1x Factory Certificate of Conformance

Ordering & Shipping Details

📦 Lead Time: Estimated 8–10 Weeks
📍 Shipping Terms: Shipping Not Included / Worldwide Shipping Available
💳 Payment Options: Credit Card, PayPal

FAQs:

Is the entire system explosion proof?
No. This model features a hazardous-rated indoor evaporator only. The outdoor condenser is a general-purpose unit and must be installed in a non-hazardous area.

What hazardous area certification does this mini split have?
The indoor section is certified for Class I Division 2 Groups B, C, and D hazardous locations.

Can the outdoor condenser be installed in a hazardous location?
No. The condenser included with this model is general purpose only. If both units require hazardous location certification, please contact us for the fully certified configuration.

Does this system provide both cooling and heating?
Yes. This mini split is a heat pump system providing both 33,600 BTU cooling and 34,000 BTU heating capacity.