Your cart is empty.

Engineered for critical oil and gas processing and hazardous environments, the Datcon DT9500 / DT9502 is an ATEX Zone 1/2 certified intrinsically safe resistance thermometer and 4–20 mA loop-powered transmitter. Supporting 3- or 4-wire Pt100 inputs with high-precision curve fitting, it delivers dependable local indication and signal retransmission across severe operating conditions.
| Country of Origin | Hungary (HU) |
| Brand | Datcon |
| Certification | ATEX Zone 1, Zone 2 (II 1G Ex ia IIC T4 Ga) |
| Model & Enclosure Type | DT9500 WM - Wall Mounting (IP65 Polycarbonate), DT9500 PM - Panel Mounting (IP65 Polycarbonate), DT9502 PM - DIN Panel Mounting 144x72mm (IP65/IP30) |
The Datcon DT9500 and DT9502 Intrinsically Safe Resistance Thermometers / Transmitters deliver reliable temperature measurement and local visual monitoring directly in potentially explosive plant areas (ATEX Zone 1 and Zone 2). Engineered specifically for harsh chemical processing, upstream and downstream oil and gas plants, and process facilities, this instrument connects to standard Pt100 resistance temperature sensors via 3-wire or 4-wire configurations to eliminate lead resistance errors and maintain process integrity.
Operating as a two-wire, 4–20 mA loop-powered transmitter, the instrument allows user-assigned temperature ranges with calibrated 3-point sensor curve fitting for exceptional measurement accuracy. An ultra-clear 4 ½ digit LCD with large 20.5 mm character height ensures instant readability across dark or distant field locations, while front-panel membrane push-buttons allow quick on-site calibration and setup secured by two-level password protection.
✅ ATEX Certified: II 1G Ex ia IIC T4 Ga for Zone 1 and Zone 2 hazardous areas
✅ Microcontroller-based technology with EEPROM storage & two-level password security
✅ IP65-rated polycarbonate field/panel housing (DT9500) or DIN ABS panel housing (DT9502)
✅ 4–20 mA two-wire loop-powered analog output (12–30 V operating voltage)
✅ 4 ½ digit 7-segment LCD display with 20.5 mm character height for field visibility
✅ Two optically isolated transistor limit outputs for setpoint signaling and alarm control
✅ Wide measuring range from -200 °C to +600 °C with ±0.3 °C basic accuracy
✅ 3-point sensor curve fitting and selectable digital signal filtering
✅ Three tactile front-panel membrane push-buttons for on-site programming
🔹 DT9500 (Field / Panel Mount): Robust moulded polycarbonate housing with cable glands, IP65 ingress protection, direct push-in terminals
🔹 DT9502 (Panel Mount): Standard 144 x 72 mm DIN ABS enclosure, IP65 front / IP30 rear, push-in terminal connection
| Feature | Details |
|---|---|
| Model Variants | DT9500 (Field/Panel, Polycarbonate) / DT9502 (DIN Panel, ABS) |
| Hazardous Area Certification | ATEX: BKI 15 ATEX 0028 X |
| Ex Classification Marking | II 1G Ex ia IIC T4 Ga (-20 °C < Ta < +60 °C) |
| Sensor Input | Pt100 resistance thermometer (3-wire or 4-wire connection) |
| Measuring Range | -200 °C to +600 °C |
| Sensor Measuring Current | 800 µA |
| Measurement Accuracy | < 0.3 °C (-200 °C < Tp < +400 °C); < 0.4 °C (+400 °C < Tp < +600 °C) |
| Sampling Rate / Averaging | 15 measurements/sec; selectable averaging (1, 2, 4, 8, 16, 32 samples) |
| Analog Output | 4–20 mA DC (two-wire loop-powered); overrange up to 21 mA |
| Analog Output Accuracy | 0.02% @ 23 °C ± 2 °C; 0.15% @ -20 °C to +60 °C |
| Limit Outputs | 2 optically isolated passive switching transistors (Load: 10 V, 16 mA max) |
| Display | 4 ½ digit 7-segment LCD, 20.5 mm character height, decimal & negative sign |
| Display Refresh Rate | Selectable: 0.1, 0.3, 0.5, 1.0, 2.0 seconds |
| Power Supply | 12–30 V DC (loop-powered), reverse polarity protected |
| Electrical Safety (Pt100) | Uo = 6.6 V, Io = 9 mA, Po = 15 mW, Co = 2 µF, Lo = 10 mH |
| Electrical Safety (4–20 mA) | Ui = 30 V, Ii = 100 mA, Pi = 0.75 W, Ci = 48 nF, Li ~ 0 |
| Electrical Safety (Limits) | Ui = 10 V, Ii = 16 mA, Pi = 40 mW, Ci = 0, Li ~ 0 |
| Operating Temperature | -20 °C to +60 °C; Relative Humidity: 90% max (non-condensing) |
| Ingress Protection | DT9500: IP65; DT9502: IP65 front, IP30 rear |
| Dimensions (W x H x D) | DT9500: 167 x 87 x 90 mm; DT9502: 144 x 72 x 75 mm |
| Weight | DT9500: 0.8 kg; DT9502: 0.4 kg |
| EMC Compliance | EN 61326-1 (Immunity: Industrial areas; Emission: Group 1, Class B) |
🔗 ATEX Certificate BKI 15 ATEX 0028 X – II 1G Ex ia IIC T4 Ga (-20 °C < Ta < +60 °C)
🔗 EN 61010-1 Safety Compliance – Pollution Level 2, Measurement Category II electrical isolation
🔗 EN 61326-1 EMC Compliance – Industrial immunity and Group 1 Class B emission limits
🔗 Ingress Protection – IP65 full housing (DT9500) / IP65 front, IP30 rear (DT9502)
🔗 Download Datasheet
🔹 Oil & Gas
🔹 Chemical Plants
🔹 Mining
🔹 Labs
🔹 Manufacturing
📦 1x Datcon DT9500 or DT9502 Intrinsically Safe Resistance Thermometer / Transmitter
📦 1x Integrated Push-in Terminal Connection Block
📦 1x IP65 Cable Gland Assembly (DT9500 model)
📦 1x Panel Mounting Hardware Kit
📦 1x Manufacturer Calibration & Inspection Certificate
📦 1x Documentation Kit (Operating Manual & ATEX Safety Instructions)
📦 Lead Time: 2 - 3 weeks
📍 Shipping Terms: Worldwide / Expedited Options
💳 Payment Options: Credit Card, PayPal, Net 30 Terms
🔗Zone 1/2 DATCON Digital Clock
What input types are supported by the DT9500 / DT9502?
The unit accepts standard Pt100 RTD resistance inputs in either 3-wire or 4-wire configurations, allowing for line resistance
No reviews yet — be the first to review this product.