The MadgeTech RHTEMP1000EX Temperature and Humidity Data Logger is ATEX Zone 0, 1, and 2 approved for usage in hazardous environments. With IECEx and FM certifications to back it up. Measures and records temperatures between (-40 degrees Fahrenheit) and (176 degrees Fahrenheit) with an accuracy of (0.4 degrees Celsius) and (0.9 degrees Celsius). From 0% RH to 100% RH may be measured with this device (non-condensing). An RTD sensor and Capacitive Polymer Humidity Sensor are also included in the stainless steel shell. It can save 32,767 time and date-stamped values and may be configured to start 24 months in advance.
| ATEX Rating | Zone 0 |
| IECEx Certified | Yes |
The MadgeTech RHTEMP1000EX is an Intrinsically Safe Temperature and Humidity Data Logger that is approved for usage in ATEX Zones 0, 1, and 2. With IECEx and FM certifications to back it up. The stainless steel casing and wide temperature range (-40°C to +80°C) are only two of the numerous benefits of these intrinsically safe data loggers.
For up to 24 months in advance, the RHTemp1000Ex can save up to 32,767 times and date stamped readings. It is also more widely accepted and helps people who have to follow strict rules while working in dangerous settings.. Logging devices for use in explosive settings have been developed expressly for this purpose.
The RHTemp1000Ex is compatible with the latest MadgeTech 4 Software making starting, stopping, and downloading simple and easy. Graphical, tabular, and summary data is provided for analysis and can be viewed as customizable engineering units.
| General | |
| Memory | 32,767 readings |
| Reading Rate | 1 reading every 2 seconds up to 1 reading every 12 hours |
| Battery Life | 2 years typical at 15 minute reading rate |
| Material | 316 Stainless Steel/Radel |
| Dimensions | 1.7 in x 0.97 in x 0.97 in (42 mm x 24.6 mm x 24.6 mm) |
| IP Rating | (Not Rated) Caution: Do not submerge this product to retain IS rating. |
| Operating Environment | -40 °C to +80 °C (-40 °F to +176 °F), 0 %RH to 95 %RH (case properly sealed) |
| Required Interface Package | IFC400 or IFC406 |
| Approvals | CE |
| ATEX | |
| IECEx | |
| FM 3610 | |
| Temperature | |
| Temperature Sensor | Resistance Temperature Detector (RTD) |
| Temperature Range | -40 °C to +80 °C (-40 °F to +176 °F) |
| Temperature Resolution | 0.01 °C (0.018 °F) |
| Temperature Calibrated Accuracy | ±0.5 °C (0 °C to 55 °C), ±0.9 °F (32 °F to 122 °F) |
| Humidity | |
| Humidity Sensor | Capacitive Polymer |
| Humidity Range | 0 %RH to 100 %RH (non-condensing) |
| Humidity Resolution | 0.1 %RH |
| Humidity Calibrated Accuracy | ±3 %RH maximum |
| Humidity Specified Accuracy Range | 25 %RH to 75 %RH |
| +20 °C to +40 °C | |
| Hysteresis Error 1 % Typical, | |
| 3% Maximum |