Intrinsically Safe Store Logo
Intrinsically-Safe-Fire-Investigation-Kit-Ion-Science-Tiger-ATEX-certified
ATEX Zone 0 Gas Detector

Ion Science Tiger Fire Investigation Gas Detector Kit

In Stock
SKU:
$5,199.44
Qty
1

Safety Specifications

Incl. accredited factory seal & certification stamps
ZoneZone 0
Product Description

Ion Science Tiger Intrinsically Safe Fire Investigation Kit is ATEX Zone 0 and IECEx approved. The ION Science Fire Investigation Kit with Tiger or Tiger LT photoionization detector (PID) has been built specifically to offer you all the equipment necessary for a practical, easy-to-use solution for detecting volatile organic compounds (VOCs) in Fire and Arson Investigation applications. For arson investigations, the Tiger and Tiger LT PIDs are excellent. They feature a durable design, are ready to use in seconds, and are suitable for use while wearing gloves.

Technical Datasheet

Certification & Specification

Country of OriginUnited Kingdom (GB)
ATEX Safety / ZoneZone 0

Product Overview

In order to provide you with a straightforward, easy-to-use solution for the detection of volatile organic compounds (VOCs) in Fire and Arson Investigation applications, ION Science has developed the Fire Investigation Kit with Tiger or Tiger LT photoionization detector (PID).

It is an element of the fire investigation in cases of suspected arson to prove that there was no other source of the fire. Hydrocarbon chemicals such as petrol, alkanes, and cycloalkanes can be detected with the Fire Investigation Kit. It is the job of fire investigators to look for every form of accelerant in the event of a fire, from grill lighters and lighter fuel to liquid glue and cleaning solvents.

Features:

  • ATEX Zone 0
  • IECEx
  • 10.6 eV Krypton PID lamp (standard)
  • 10.0 eV and 11.7 eV lamp optional
  • Li-Ion battery
  • Integrated Flashlight
  • Bump Test Pen
  • AA Tiger battery pack
  • Charging cradle
  • Travel charger adaptor
  • PTFE filters
  • IP65 (heavy rain)

Specifications:

TIGER LT SPECIFICATIONS
Minimum resolution* 0.1 ppm
Maximum reading 5,000 ppm
Response time T90 < 2 seconds
Accuracy* 5% display reading one digit
Linearity* 5% display reading one digit
Intrinsically safe approvals II 1G Ex ia IIC T4 Ga
Tamb = - 15 0C ≤Ta ≤+45 0C (with lithium ion battery pack)
Tamb = - 15 0C ≤Ta ≤+40 0C (with alkaline battery pack)
ITS09ATEX26890X IECEx ITS 10.0036X
3193491 conforms to UL Std. 913, 61010-1 &
Certified to CAN/CSA Std. C22.2 No. 61010-1
Battery life Li-ion: life up to 24 hours continual use
Lamps 10.6 eV Krypton PID lamp (standard.)
Data logging Push-to-log, 128 zones, 80,000 data points
Calibration Standard calibration 100 ppm isobutylene
Custom calibration capability
Alarm Flashing LED and 95 dBA at 300mm (12”) audible sounder
Selectable vibrating alarm
Flow rate 220 ml/min in ambient conditions (with blocked flow alarm)
Temperature Operating: -20 to 60 0C, -4 to 140 0F (non-Intrinsically Safe)
Humidity: 0-99% RH (non condensing)
Protection Designed to IP65 (heavy rain)
1180
EMC tested to EN61326- 1:2006, EN50270:2006 & CFR 47:2008 Class A
Weight & dimensions Instrument (with probe)
Width: 91.4 x Height: 370 x
Depth: 61 mm (3.59 x 14.56 x 2.4”)
Instrument weight 0.75 kg
TIGER SPECIFICATIONS
Minimum resolution* 1 ppb or 0.001 mg/m3
Maximum reading 20,000 ppm or 20,000 mg/ m3 (gas dependent)
Response time T90 < 2 seconds
Accuracy* 5% display reading one digit
Linearity* 5% display reading one digit
Intrinsically safe approvals II 1G Ex ia IIC T4 Ga
Tamb = - 15 0C ≤Ta ≤+45 0C (with lithium ion battery pack)
Tamb = - 15 0C ≤Ta ≤+45 0C (with alkaline battery pack)
ITS09ATEX26890X IECEx ITS 10.0036X
3193491 conforms to UL Std. 913, 61010-1 &
Certified to CAN/CSA Std. C22.2 No. 61010-1
Battery life Li-ion: life up to 24 hours continual use
Alkaline: (Duracell Procell MN 1500) life up to 8.5 hours continual use
Lamps 10.6 eV Krypton PID lamp (standard.) 10.0 eV and 11.7 eV lamps available
Data logging Including date / time: 120,000 points
Communication Direct USB 1.1 connection
Alarm Flashing LED and 95 dBA at 300mm (12”) audible sounder
Selectable vibrating alarm
Pre-programmed TWA and STEL*
Pre-programmed with over 700 gases*
Flow rate 220 ml/min in ambient conditions (with blocked flow alarm)
Temperature Operating: -20 to 60 0C, -4 to 140 0F (non Intrinsically Safe)
Humidity: 0-99% RH (non condensing)
Protection Designed to IP65 (heavy rain)
1180
EMC tested to EN61326-1:2006, EN50270:2006 & CFR 47:2008 Class A
Weight & dimensions Instrument with probe
Width: 340 x Height: 90 x Depth: 60 mm (13.4 x 3.6 x 2.4”)
Standard case
367 x 89 x 90 mm (14.45 x 3.54 x 2.36”)
Instrument weight 0.72 kg (1.56lb)
Packed weight: 5 .5kg (12lb)