The rugged pressure recorder Madge Tech PRTEMP1000IS is certified for usage in Class I Division I hazardous environments. This certification qualifies the device for usage in hostile environments such as air conditioning systems, chilled water, and hot water systems, as well as air, gas, oil, and steam pressure systems. Additionally, this gadget measures and records pressure and temperature accurately at user-programmable reading intervals.
Among the many outstanding features are the internal temperature sensor, which offers reliable temperature readings without the need for a separate temperature recorder. The logger can be configured to take readings as frequently as every two seconds, up to once every twelve hours. Its non-volatile memory will record up to 16,383 readings.
Additionally, it includes a robust stainless steel pressure strain gauge for reliable pressure measurement. This device is equipped with a standard 14 in. NPT fitting is available in pressure ranges of 30 to 500 PSI.
MadgeTech Software is a robust analytic tool that is accessible for free download from our website at www.madgetech.com. The data can be examined graphically or tabulated, and summary and statistics views are provided for additional analysis.
Features:
- Class I Division I
- Intrinsically safe
- Rugged
- 1/4” NPT pressure port
- Programmable start time
- Real-time operation
- User-friendly
- Low cost
- Stainless Steel
- Semiconductor Sensor
- Lithium Battery: 3.6 V
Versions
- 0 to 1000 PSIA Intrinsically Safe Pressure & Temperature Recorder w/ 1/4″ NPT fitting, stainless steel enclosure
- 0 to 100 PSIA Intrinsically Safe Pressure & Temperature Recorder w/ 1/4″ NPT fitting, stainless steel enclosure
- 0 to 100 PSIG Intrinsically Safe Pressure & Temperature Recorder w/ 1/4″ NPT fitting, stainless steel enclosure
- 0 to 300 PSIA Intrinsically Safe Pressure & Temperature Recorder w/ 1/4″ NPT fitting, stainless steel enclosure
- 0 to 300 PSIG Intrinsically Safe Pressure & Temperature Recorder w/ 1/4″ NPT fitting, stainless steel enclosure
- 0 to 30 PSIA Intrinsically Safe Pressure & Temperature Recorder w/ 1/4″ NPT fitting, stainless steel enclosure
- 0 to 30 PSIG Intrinsically Safe Pressure & Temperature Recorder w/ 1/4″ NPT fitting, stainless steel enclosure
- 0 to 5000 PSIA Intrinsically Safe Pressure & Temperature Recorder w/ 1/4″ NPT fitting, stainless steel enclosure
- 0 to 500 PSIA Intrinsically Safe Pressure & Temperature Recorder w/ 1/4″ NPT fitting, stainless steel enclosure
- 0 to 500 PSIG Intrinsically Safe Pressure & Temperature Recorder w/ 1/4″ NPT fitting, stainless steel enclosure
Software Features:
- Multiple graph overlay
- Statistics
- Digital calibration
- Zoom in/ zoom out
- Lethality equations (F0, PU)
- Mean Kinetic Temperature
- Full-time zone support
- Data annotation
- Min./Max./Average lines
- Data table view
- Automatic report generation
- Summary view
- Multilingual
Software Key:
- Graph View
- Tabular Data View
- Statistics
- Digital Calibration
- Copy to Excel®
Applications
- Oil & gas industries
- Pneumatics
- Process control systems
- Gas compressors
- Natural gas production
- Lubrication systems
- Chemical processing
- Pulp and paper processing
- Medical instrumentation
- Environmental studies
- Wastewater treatment
- HVAC
- Refrigeration
Specifications
Temperature Sensor: | Semiconductor |
---|---|
Temperature Range: | -40 ºC to +80 ºC (-40 ºF to +176 ºF) |
Temperature Resolution: | 0.1 ºC (0.18 ºF) |
Calibrated Accuracy: | ±0.5 ºC (±0.9 ºF) |
Pressure Sensor: | Semiconductor strain gauge |
Pressure Range: | 0 to 30, 100, 300 and 500 PSIA/G; |
0 to 1000 and 5000 PSIA | |
Pressure Resolution: | 0.002, 0.005, 0.02, 0.05 PSIA/G; |
0.05, 0.2 PSIA | |
Calibrated Accuracy: | 2 %FSR, 0.25 % @ 25 ºC typical |
Pressure Response Time: | 0.1 ms (10 to 90 %FSR) |
Repeatability: | ±0.5 %FSR; ±0.2 % typical |
Adaptor: | 1/4” male NPT |
Start Modes: | Software programmable immediate start or delay start up to six months in advance |
Real Time Recording: | May be used with PC to monitor and record data in real time |
Memory: | 16,383 readings per channel; |
32,766 total readings | |
Reading Rate: | 1 reading every 2 seconds up to 1 reading every 12 hours |
Calibration: | Digital calibration through software |
Calibration Date: | Automatically recorded within device |
Battery Type: | 3.6 V lithium battery included; user replaceable |
Battery Life: | 1 year typical (1 minute reading rate @ 25 ºC) |
Data Format: | Date and time stamped ºC, ºF, K, ºR ; PSIA(g), inches, feet, mmHg, bar, Torr, kPa, |
Time Accuracy: | ±1 minute/month |
(at 20 ºC, RS232 port not in use) | |
Computer Interface: | PC serial or USB (interface cable required); |
2,400 baud | |
Software: | XP SP3/Vista/Windows 7/Windows 8 |
Operating Environment: | -40 ºC to +80 ºC (-40 ºF to +176 ºF), |
0 %RH to 100 %RH | |
Dimensions: | 6.4 in x 1.25 in dia. (163 mm x 32 mm dia.) |
Weight: | 12 oz (340 g) |
Material: | Stainless Steel |
Approvals: | CE |
FM Certified Intrinsically Safe for Class I, Division 1 groups A, B, C and D | |
BATTERY WARNING: RISK OF FIRE OR EXPLOSION. DO NOT RECHARGE, FORCE OPEN, HEAT OR DISPOSE OF IN FIRE. |
What others are saying