The DATCON DT4V5BAT is an ATEX-certified intrinsically safe 4.5 VDC primary battery pack engineered for safe, reliable power in Zone 1 and Zone 2 hazardous process instrumentation. Designed for seamless plug-and-play integration with DATCON DT9100 and DT9102 field indicators, it ensures non-stop monitoring and compliance in explosive oil, gas, and chemical environments.
| Country of Origin | Hungary (HU) |
| ATEX Rating | ATEX II 2 G Ex ib [ia Ga] IIC T4 Gb / Ex ib [ia Ga] IIB T4 Gb |
The DATCON DT4V5BAT is a certified intrinsically safe (Ex) factory-assembled primary battery pack engineered specifically to deliver dependable power to DATCON process control instrumentation operating in hazardous explosive environments. Designed for direct installation in ATEX and IECEx Zone 1 and Zone 2 areas, it ensures uninterrupted performance for critical digital indicators, field displays, and loop monitors without compromising the overall loop certification.
Built with a hermetically encapsulated internal assembly and integrated short-circuit protection, this 4.5 VDC battery pack provides over 2 years of continuous standard service across extreme field temperatures from -20°C to +60°C. Its snap-in connector harness allows quick, foolproof maintenance swaps, ensuring zero downtime and complete intrinsic safety compliance for process monitoring equipment in demanding industrial facilities.
✅ ATEX II 2 G Ex ib [ia Ga] IIC T4 Gb / Ex ib [ia Ga] IIB T4 Gb certified
✅ EN 60079-0 and EN 60079-11 intrinsic safety compliance
✅ 4.5 VDC nominal voltage high-reliability primary electrochemical system
✅ Direct snap-in internal connector harness for secure installation
✅ Integrated short-circuit current limiting mechanism for maximum fault protection
✅ Hermetically encapsulated potting to isolate internal cells from hazardous atmospheres
✅ Extended service life of ≥ 2 years continuous standard operation
✅ Broad operating temperature range from -20°C to +60°C matching host transmitter specs
✅ Dedicated OEM replacement engineered exclusively for DATCON DT9100 and DT9102 series
🔹 Standard Pack: Single OEM DT4V5BAT sealed battery assembly with hazardous area safety labeling
🔹 Multipack / Facility Spares: Multi-unit packaging available for scheduled plant-wide maintenance turnarounds
| Feature | Details |
|---|---|
| Manufacturer / Brand | DATCON Kft. (Budapest, Hungary) |
| Model / Part Number | DT4V5BAT |
| Component Classification | Intrinsically Safe (Ex) Replacement Battery Assembly |
| Cell Chemistry | High-reliability primary electrochemical system (Non-rechargeable) |
| Nominal Supply Voltage | 4.5 VDC |
| Expected Service Life | ≥ 2 years continuous standard operation (dependent on ambient temp & update rate) |
| Hazardous Area Classification | ATEX II 2(1) G Ex ib [ia Ga] IIC T4 Gb Ex ib [ia Ga] IIB T4 Gb (installed in host) |
| Compliance Standards | EN 60079-0, EN 60079-11 |
| Permissible Operating Temperature | -20°C to +60°C (-4°F to +140°F) |
| Storage Temperature | +10°C to +25°C in dry, non-corrosive atmosphere |
| Internal Safety Features | Hermetically encapsulated potting integrated short-circuit current limiting mechanism |
| Connection Type | Direct snap-in internal connector harness |
| Host Instrument Compatibility | DATCON DT9100, DT9100 I, DT9100 B DT9102, DT9102 I |
| Packaging & Origin | Single unit sealed pack with safety labeling European Union (Hungary) |
🔗 ATEX Certificate – II 2 G Ex ib [ia Ga] IIC T4 Gb / Ex ib [ia Ga] IIB T4 Gb
🔗 EN 60079-0 & EN 60079-11 – Explosive atmospheres general requirements and intrinsic safety "i" standards
🔗 Hermetic Encapsulation – Protects against spark ignition, chemical ingress, and internal component exposure
🔗 IP Rating – Meets/maintains host enclosure environmental ingress protection when properly installed
🔗 Download Datasheet
🔹 Oil & Gas (Upstream Wellheads, Refineries, Offloading Terminals)
🔹 Chemical Plants & Petrochemical Processing Facilities
🔹 Mining & Mineral Extraction Monitoring
🔹 Labs & Testing Pilot Plants
🔹 Manufacturing & Industrial Hazardous Process Control
📦 1x DATCON DT4V5BAT 4.5 VDC Intrinsically Safe Battery Pack
📦 1x Integrated Wiring Harness with Polarized Connector
📦 1x Manufacturer Safety Instruction & Compliance Leaflet
📦 Lead Time: 2 - 3 weeks
📍 Shipping Terms: Worldwide / Expedited Hazardous-Rated Battery Shipping Options Available
💳 Payment Options: Credit Card, PayPal, Net 30 Terms Available for Qualified Accounts
🔗 DATCON DT9100 / DT9100 I Field Indicator & Loop Display
🔗 DATCON DT9100 B Battery-Powered Digital Clock Unit
🔗 DATCON DT9102 / DT9102 I Industrial Process Indicator
Can the DT4V5BAT battery pack be recharged?
No. The DT4V5BAT is a non-rechargeable primary electrochemical battery pack. Applying external or reverse charging current creates a serious safety hazard and is strictly prohibited in both safe and hazardous areas.
Can I rebuild or replace individual cells inside the battery pack?
No. Zero field rebuilding is permitted. Replacing individual inner cells or tampering with the harness potting completely voids the ATEX/IECEx intrinsic safety certification. The unit must always be replaced as a complete factory OEM assembly.
Which instruments are compatible with this battery?
The DT4V5BAT is engineered specifically for DATCON instruments, including the DT9100, DT9100 I, DT9100 B, DT9102, and DT9102 I series field indicators and loop displays.
Can I swap this battery directly in a hazardous location?
Disconnect and replace the battery only in accordance with the host instrument’s manual guidelines. Unless explicitly verified de-energized and certified safe by plant safety protocols, battery replacement should be performed outside the hazardous area.
No reviews yet — be the first to review this product.