Intrinsically Safe James Industry TGA Emergency Pack
The Intrinsically Safe James Industry TGA Emergency Pack represents a cutting-edge solution designed to meet the critical need for reliable emergency lighting in hazardous environments. With an unwavering commitment to safety and performance, this system stands as a pinnacle in the realm of constant power solutions for emergency lighting.
Crafted with meticulous attention to detail, the James Industry TGA Emergency Pack is meticulously engineered to deliver uninterrupted power for 120 minutes, ensuring continued illumination during crucial moments. Its inherent design for use in Class I, Division 2 hazardous (Classified) locations showcases its adaptability and compliance with stringent safety regulations. Powered by advanced microcontroller logic control technology, this emergency pack achieves unparalleled self-diagnostic capabilities, assuring not just illumination but also operational integrity. The inclusion of high-efficiency components, boasting up to 90% efficiency, underlines its commitment to optimized performance and energy conservation.
With a suite of protective measures, including safeguards against short circuits, over-current situations, and over-voltage occurrences, this system offers a fortified shield against potential hazards, safeguarding both the equipment and the connected lighting fixtures. Moreover, its compatibility with various light fixtures, especially LED lighting and electronic screen applications, ensures versatility and adaptability in diverse settings.
The dedication to reliability is evident in every facet of this emergency pack, from the glue-filled compartments that shield internal components against high temperatures to the integration of constant current limiting circuitry, guaranteeing a stable and consistent flow of power. Certified in accordance with worldwide safety regulations, including UL, CE, and RoHS certifications, the James Industry TGA Emergency Pack stands as a beacon of compliance and assurance in the realm of emergency lighting solutions.
In summary, this meticulously crafted system embodies innovation, safety, and reliability, catering to the stringent demands of hazardous environments while ensuring uninterrupted illumination for critical durations.
Features:
- 120 minutes of emergency lighting: The system is capable of providing a constant power supply for up to 120 minutes during emergency situations. This duration ensures an extended period of illumination, crucial for safety and navigation in case of power outages or emergencies.
- Type “HL” for Class I, Division 2 hazardous locations: Indicates that the equipment is suitable for potentially explosive atmospheres.
- Microcontroller logic control technology for self-diagnosis: This technology likely enables the system to perform self-checks and diagnostics to ensure functionality and reliability.
- High efficiency up to 90%: Indicates that the system is designed to minimize energy loss during operation, maximizing its effectiveness.
- Protection features: The system includes protection against short circuits, over-current situations, and over-voltage scenarios, safeguarding both the equipment and connected fixtures.
- Compatibility with various light fixtures: Designed to work with different types of lighting systems, offering flexibility.
- Glue-filled battery and control compartments: This feature aims to protect internal components from high temperatures, potentially increasing the lifespan of the system.
- Built-in constant current limiting circuit: Ensures a steady and controlled flow of current to the lighting fixtures, which is particularly crucial for LED and electronic screen applications.
- High reliability: Focuses on providing a dependable and consistent power supply for emergency lighting needs.
- Suitability for LED lighting and electronic screen applications: Indicates compatibility with modern lighting technologies.
- Compliance with worldwide safety regulations: The system meets safety standards such as UL (Underwriters Laboratories), CE (Conformité Européenne), and RoHS (Restriction of Hazardous Substances), ensuring it meets international safety requirements.
Specifications:
Technical Data | |
Specifications (Controller) | |
Driver Model | l EM-15W-HL(A) |
Input Rating | AC 100-277V, 50/60 Hz |
Max. A: 0.15 | |
Max. W: 9 | |
Output Rating | DC42-50V (Max.) |
Constant Wattage: 15W | |
Specifications (Battery) | |
Battery Model | EM-15W-HL(B) |
Response Time | ≤1 second |
Charge Time | ≥24 hours |
Quick charging for the first 2 hours, followed by trickle charging. It will stop charging when the driver is fully charged. Once the battery level is below 100%, trickle charge comes in again. | |
Battery Capacity | INR18650-2000mAh |
4S1P | |
Cell Rating: 3.7V 2000mAh | |
Total Rating:14.8V, 2000mAh | |
Emergency Time | 90 mins |
Use Environment | Wet location |
Ambient Range | -10℃~60℃ |
Battery Life Expectancy | 5 years |
Indicator | Discharge: The indicator light will be yellow when the remaining battery is below 20% |
Charge: The indicator light will be red when the battery charge level is between 20% and 80%. When it hits 80%, the light will turn green. |
Installation Instruction:
Installation Instruction | |
Venas EX-proof Light Series | Emergency Pack Components |
A,A3,A4,B3,B4,C,C3,D,H,I, STA,R Series Luminaires | TGA(Controller + Battery) |
A2,B2,G,O,C2,D2 Series Luminaires | TGA(Controller + Battery) + EX-proof Box (ES03C2) |
What others are saying