Explosion Proof Control Panel TLH214AG3 CC

SKU: TLH214AG3CC

The Explosion Proof Control Panel TLH214AG3 CC has an explosion protection rating of Ex d IIB T6 Gb and a dust and moisture protection rating of IP 66. It has a nominal power of 15 W and can produce call power of up to 120 dB/m. Additionally, it features a noise-canceling microphone.

$4,32000

Shipping Time: 2-6 weeks

Need faster options? Contact our Hazardous Areas Experts now for quick alternatives!

Trusted Clients

  • Logo PH66
  • Logo  Exxon
  • Logo Bp
  • Logo Conoco Phillipis
  • Logo Irwing
  • Logo Bayer
  • Logo Tesoro
  • Logo Northen TIer
  • Logo Udelhoven
  • Logo Aloha petroleum
  • Logo Rand
  • Logo Arrow Energy
  • Logo Schlumber
  • Logo Afton
  • Logo Holly frontier
Similar Category:

Explosion Proof Control Panel TLH214AG3 CC

The Explosion Proof Control Panel TLH214AG3 CC has an explosion protection rating of Ex d IIB T6 Gb and a dust and moisture protection rating of IP 66. It has a nominal power of 15 W and can produce call power of up to 120 dB/m. Additionally, it features a noise-canceling microphone.

Features

-Aluminum alloy body with anti-corrosion coating
– Explosion protection marking for gas: 1Ex db IIB T6 Gb X, against ignition of combustible dust Ex tb IIIC T85°С Db X
– Protection level against dust and moisture: IP66
– Vandal-proof design, impact resistance: IK10 (20 J)
– Sealed keyboard, programmable keys
– Hands-free speakerphone function
– Sound pressure level: up to 116 dB at 1 m
– Connection: 1-pair, “loop” or “star” topology
– Power supply: ±24Vdc, ±48Vdc or
230Vac
– Operating temperature range: from -40°С to +60°С
– Overall dimensions: 215x350x195 mm / Weight:
8.6 kg

Electrical characteristics:

Supply voltage: 48 Vcc (24V optional)
Max consumption: 300 mA
Standby consumption: 24 mA
Max supply voltage: 38-72V
Max dissipation power * : 15 Watts *
Ringing level: >100 dB / 1 m.
Optical signal: optional
Conversation mode: hands-free driven

Material and Construction

Material / Color:.…………..……….aluminium light alloy / RAL2003
Microphone:………………………….………weatherproof electret type
Loudspeaker:…………….…………….….…………..driver unit 15 watts
Fixing:……..……………..…………………wall mouting on 3 holes Ø10
Termination:………………………………unplugable screw connectors
Cable type:……………….…………………….…max section of 1.5mm²
Cable glands:………………………Ex cable type from Ø7 to Ø12mm
Dimensions:…..……………………………………..210 X 300 X 190 mm
Weight:…………………………..……………………………………….8,6 kgs
Specific marking:……..……..II2G (Gas) or Ex II2GD (Gas & Dust)
Additional marking:……..………………………….……Ex dIIBT6 / II2G
tD A21 IP6X T85°C/ II2GD
EC type examination certificate:….………….INERIS 03ATEX0238X

**Commissioning and Operation:**

The instructions provided should be read in conjunction with the following:

1. Standard NF C 15 100.
2. European directive ATEX 94/9/CE of March 1994 and its annexes.
3. Standard EN 60 079-14 (electrical installations in explosive gas atmospheres).
4. Standard EN 60 079-17 (inspection and maintenance in hazardous areas).
5. Decrees, laws, directives, circulars, applications, standards, rules of art, and documents concerning the installation place.
6. EN 61241-14: selection and installation.
7. EN 61241-17: inspection and maintenance of electrical installations in hazardous areas (other than mines).

Non-compliance with these instructions does not hold us responsible. The installation of the material should be carried out by qualified, competent, and authorized individuals. It is essential to ensure compatibility between the information on the nameplate, the current explosive atmosphere, the area of use, and the ambient and surface temperatures.