Ion Science Falco TAC Fixed VOC Detector 2026

SKU: FA2BSXBXX-50D, FA2BSXBXX-50P

The ION Science Falco 2 TAC is a premier intrinsically safe, fixed-head VOC monitor engineered for continuous detection of toxic gases in Zone 1 hazardous oil and gas environments. Featuring patented Typhoon and Fence Electrode technologies, this rugged detector eliminates false readings in high-humidity applications while providing real-time Modbus and 4-20mA telemetry.

Weight 6.39 lbs
ATEX Rating

IECEx Certified

Country of Origin 🇬🇧 United Kingdom (UK)

$6,82000

Price Depends on product option Make a selection to update price
$682 Import tariffs will be applied

Shipping Time

2 - 3 Weeks

Need faster options? Contact our Hazardous Areas Experts now for quick alternatives!

Found It Cheaper?

We Match It!
Price Match Guarantee

Need Help?

Speak with a Hazardous Area expert now

Description

ION Science Falco 2 TAC VOC Monitor

The ION Science Falco 2 TAC Intrinsically Safe Fixed VOC Gas Detectors represent the pinnacle of fixed photoionization detection (PID) technology. It is purpose-built for continuous monitoring of volatile organic compounds (VOCs) and Total Aromatic Compounds (TACs) in hazardous locations.

When evaluating equipment for hazardous environments, many safety managers are now considering the advanced ION Science Falco 2 TAC Intrinsically Safe Fixed VOC Gas Detectors. Moreover, they are certified for ATEX, IECEx, and North American Zone 1 environments.

These devices provide reliable, life-saving ambient air safety telemetry across refineries, chemical plants, and heavy industrial facilities. In these places, explosive or toxic gases pose an everyday risk.

In the field, the Falco 2 series delivers unrivaled operational resilience through its patented Typhoon Technology. This prevents condensing moisture from disrupting the PID sensor. Furthermore, Fence Electrode Technology mitigates dust contamination. Users can effortlessly navigate settings without a hot work permit using the high-contrast white-on-black OLED display. The tamper-proof 5-magnetic-switch interface is operated via a magnetic pencil—ensuring the flameproof ExD housing remains completely sealed during maintenance.

Key Features:

✅ ATEX/IECEx Zone 1 (Ex db ib IIC T4 Gb) and North American Class I, Zone 1 hazardous area certificationsbr/p>

ION Science Falco 2TAC Technical Specifications:

FeatureDetails
Detector PrinciplePhoto-Ionization Detector (PID)
Lamp Energy10.0 eV
Target SpeciesTotal Aromatic Compounds (TACs) / Benzene
Detection Range0 to 50 ppm
Resolution0.01 ppm
Accuracy±5% or ±1 digit
Electrode StackTAC Stack (White with a Gold Spot)
Sensor VariantMiniPID 2 Falco TAC
Response Time (T90)Pumped: < 10 seconds / Diffused: < 30 seconds
Measuring IntervalUser programmable: 0 to 10 minutes (1-second steps)
PID Lamp LifetimeUp to 10,000 hours from date of delivery
Display ScreenHigh-contrast white-on-black OLED (128 x 64 pixels)
User Interface5 magnetic switches with LED confirmation (up, down, left, right, enter)
Status IndicatorTri-color LED (Red, Amber, Green) visible from 20 meters in direct sunlight
Analog OutputGalvanically isolated 4-20 mA current loop
Digital InterfaceRS-485 Modbus RTU
Relays2 x SPDT (configurable NO & NC options; 60 VDC/2 A or 50 VAC/2 A max load)
Pumped Flow Rate260 cc/min (Pumped model only)
Nominal Voltage8 V to 40 VDC
Power ConsumptionTypical: 2 W / Maximum: 8 W
Ingress ProtectionIP65 (Main Unit and Sensor Head)
Operating TemperatureDiffused: -40°C to 50°C / Pumped: -20°C to 50°C
Operating Humidity0 to 100% RH (condensing; featuring Typhoon Technology)
Cable GlandsM25 x 1.5 ExD (Cable diameter 13 to 18 mm)
WeightDiffused: 2.5 kg / Pumped: 2.9 kg
Dimensions (H x W x D)Diffused: 223 x 192 x 115 mm / Pumped: 325 x 192 x 115 mm
Hazardous CertificationsATEX/IECEx: II 2G Ex db ib IIC T4 Gb
North American: Ex db ib IIC T4 Gb
Class I, Zone 1, AEx db ib IIC T4 Gb

Certifications & Compliance:

🔗 ATEX Certificate (FTZU 15 ATEX 0113X) – Ex db ib IIC T4 Gb compliance for European explosive atmospheres
🔗 IECEx Certificate (IECEx FTZU 16.0011X) – Global validation for safe operation within Zone 1 gas hazards
🔗 QPS North America (LR1355) – Certified for Class I, Zone 1, AEx db ib IIC T4 Gb industrial installations
🔗 Ingress Protection (IP65) – Complete protection against dust ingress and low-pressure water jets
🔗 Download Datasheet

Applications of ION Science Falco 2 & Falco 2 TAC:

🔹 Oil & Gas
🔹 Chemical Plants
🔹 Mining
🔹 Labs
🔹 Manufacturing

What’s in the Box?

📦 1x Falco 2 Fixed VOC Detector Base Unit
📦 1x MiniPID 2 Sensor (10.6 eV or 10.0 eV Lamp Pre-fitted)
📦 1x Magnetic Pencil (Part No. 873202)
📦 1x MiniPID Removal & Electrode Stack Tools
📦 1x Calibration Adapter (Diffused) or Hydrophobic Filter (Pumped)
📦 1x 2x M20 Cable Entry Glands
📦 1x Safety Notice & Documentation Kit

Ordering & Shipping Details

📦 Lead Time: 2 – 3 Weeks
📍 Shipping Terms: Worldwide / Expedited Options
💳 Payment Options: Credit Card, PayPal, Net 30 Terms

FAQs:

What is the primary difference between the Falco 2 Standard and the Falco 2 TAC?
The standard Falco 2 uses a 10.6 eV lamp to broadly detect over 700 volatile organic compounds. In contrast, the Falco 2 TAC utilizes a 10.0 eV lamp. This lamp is specifically tuned to filter out straight-chain hydrocarbons and pinpoint Total Aromatic Compounds (TACs) like Benzene.

Can the Falco 2 be calibrated and serviced inside a hazardous area?
Yes. Thanks to its dual certification and an externally located, intrinsically safe sensor head, routine maintenance, lamp cleaning, and calibrations can be executed safely in hazardous zones. This is possible without isolating the main power supply.

How does Typhoon Technology protect the sensor?
Typhoon Technology is an advanced internal design mechanism. It prevents condensing moisture from accumulating on the PID lamp window. As a result, it effectively eliminates false positive readings common in humid or outdoor coastal environments.

What are the maximum sampling distances for the pumped version?
The Falco 2 Pumped variant features an integrated flow system running at 260 cc/min. This allows it to accurately sample gases from up to 20 meters away using standard non-reactive PTFE or PVDF tubing.

Product Accessories

Make Your Job Easy. Try Our Most Popular Accessories

Ion-Science-Falco-Calibration-Adaptor-main-image

Ion Science Falco - Calibration Adaptor

SKU: 873201

Ion Science Falco - Calibration Adaptor is a push-fit calibration adaptor that connects directly to the sensor housing of the Falco fixed VOC detector. It ensures a consistent low-pressure gas delivery to the PID sensor during calibration. Shop Now!

Brand: Ion Science

In Stock 7-10 business days

$50000

$50 Import tariffs will be applied

Ion-Science-Falco-Fitted-Barb-main-image

Ion Science Falco - Fitted Barb

SKU: 5/JHS-14

Fitting Barbed M5 Pumped Falco - this barb is fitted on the side of both Pumped and Diffused units. It’s also fitted to the front of Pumped units. The hydrophobic filter is attached to the barb on pumped units for calibration. Shop Now!

Brand: Ion Science

In Stock 7-10 business days

$12520

$12.52 Import tariffs will be applied

Ion-Science-Falco-Magnetic-Actuator-main-image

Ion Science Falco - Magnetic Actuator

SKU: 873202

This replacement pen size actuator with a magnetic tip is required to set up and adjust the Falco fixed VOC detector. Shop Now!

Brand: Ion Science

In Stock 7-10 business days

$22537

$22.537 Import tariffs will be applied

ion-science-falco-pump-mounting-bracket-main-image

Ion Science Falco - Pump Mounting Bracket

SKU: 873223

Bracket Pump Mounting Falco - this bracket holds the pump in place. Shop Now!

Brand: Ion Science

In Stock 7-10 business days

$89520

$89.52 Import tariffs will be applied

Interplay

Ion Science Falco - Sensor Cover

SKU: 873206

Falco Sensor Cover is used to protect the MiniPID. The O-Ring holder sits inside the Sensor Cover with the Light Guard Protect Washer & PTFE Filter Disc. Shop Now!

Brand: Ion Science

In Stock 7-10 business days

$29577

$29.577 Import tariffs will be applied

Reviews & Questions

Share your thoughts!

Let us know what you think...

What others are saying

There are no contributions yet.

×

Login

Continue as a Guest