Because it has a minimum sensitivity of 0.001 parts per billion (ppb), the Tiger handheld VOC gas detector has the greatest measurement range of any other VOC detector now on the market. The two-second response speed of this portable, handheld detector is the fastest on the market, and it is just as quick to clear. Tiger is a battery replacement system that may be used safely in dangerous conditions. Rechargeable Li-ion batteries can be used for up to 24 hours. The instrument can be fully charged in 6.5 hours, while it may be used for 8 hours with a 1.5-hour battery charge.
In addition to the low-cost Tiger XT, the Tiger Select detects all aromatic chemicals, including benzene, and is available in the Tiger line of handheld VOC gas detectors.
Features:
- Improved robust design can withstand harsh environments
- Large internal gas table with over 750 VOCs & toxic compounds
- <2 second response time, one of the fastest and most accurate on the market
- Instantaneous alarms, RED & AMBER with loud 95 dBA sounder
- Humidity resistant and anti-contamination design ensures optimal performance
Specifications:
Minimum Resolution | 10.6 eV: 0.001 ppm (1 ppb)*** | |
11.7 eV: 0.6 ppm (600 ppb)*** | ||
Detectable Range** | 10.6 eV: 1 ppb up to 20,000 ppm*** | |
11.7 eV: 9,000 ppm***# | ||
Response Time | 10.6 eV: T90 < 2 seconds | |
11.7 eV: < 6 seconds | ||
Accuracy | 10.6 eV: +/- 5% display reading +/- one-digit *** | |
11.7 eV: +/- 12% display reading *** | ||
Intrinsically Safe Approvals | • II 1G Ex ia IIC T4 Ga | |
• Tamb = - 15 oC ≤Ta ≤+45 oC (with Lithium ion Battery Pack) | ||
• Tamb = - 15 oC ≤Ta ≤+40 oC (with Alkaline Battery Pack) | ||
• IECEx ITS 22.0025X ITS-I22ATEX35111X | ||
• ITS22UKEX0635X | ||
• 3193491 conforms to UL Std. 913, 61010-1 & Certified to CAN/CSA Std. C22.2 No. 61010-1 | ||
Battery Life (Li-ion) | Typical operating time of 24 hours | |
Charge time typically 8 hours | ||
Lamps | 10 eV Krypton | |
10.6 eV Krypton (standard) | ||
11.7 eV argon | ||
Data Loigging | >120,000 data log points including date and time stamp | |
Communication | Direct USB 1.1 | |
Calibration | 2-point and 3-point calibration (via calibration kit accessory) | |
Alarms | Flashing LEDs’s amber (low alarm) red (high alarm) | |
Sounder 95 dBA at 300 mm (12”) | ||
Vibration on alarm | ||
Pre-programmed TWA and STEL | ||
Flow Rate | ≥ 220 ml/min | |
Temperature | Operating: | |
10.6 eV: -20 to 60oC (non-Intrinsically Safe environment) | ||
11.7 eV: 0 to 60oC | ||
Certified to: | ||
10.6 eV: 15 to +45oC / +5 to +113oF (Intrinsically Safe environment) | ||
11.7 eV: 15 to +45oC / +5 to +113oF (Intrinsically Safe environment) | ||
Storage: -25 to 60oC / -5 to 140oF | ||
Humidity: 0-99% RH (non-condensing) | ||
Protection | Designed to IP65 | |
EMC tested to EN61326-1:2013 & EN50270:2015 & CFR 47:2008 Class A | ||
Weight & Dimensions | Instrument Weight: 870g | |
Instrument Dimensions: 370 mm (H) x 91 mm (W) x 60 mm (D) |