Intrinsically Safe Omni-Directional Alarm Horn & Xenon Beacon Tomar BEXCS110 Series
Features:
• Omni-directional sound output.
• Marine grade, corrosion proof, LM6 aluminum
enclosure
• Automatic synchronization on multi-beacon &
sounder systems.
• Beacons can be set to ‘flip-flop’ alternating
mode with other units on multi-beacon systems.
• Xenon tubes mechanically secured against shock
& vibration
• Very large termination area.
• Dual M20 cable entries – adaptors available.
• Stopping plug included.
• Ratchet adjustable stainless steel ‘U’ bracket.
• Reverse polarity diode fitted.
• IP66/67 ingress protection.
• 120 candela effective light intensity.
• UV stable PC, field replaceable, color lens filters.
Introducing Intrinsically Safe Omni-Directional Alarm Horn & Xenon Beacon Tomar BEXCS110 Series
The radial horn on the compact BExCS110-05-R distributes the audible warning signal omnidirectionally allowing the visual signal to be orientated optimally.
The alarm horn & Xenon beacon may be connected from a single power supply for simultaneous operation or from separate supplies for independent operation.
The BEx range features enclosures manufactured from corrosion proof, marine grade copper free LM6 aluminum with a chromate and powder coat finish. All models have two M20 cable entries, large termination areas containing in & out terminals and an ingress
protection of IP66/67.
Specifications
Sounder/Horn
Item | Description |
---|---|
Maximum output | 115dB (A) @ 1 meter [106dB (A) @ 10ft/3m] |
Nominal output | 110dB (A) @ 1m +/- 3dB - Tone 2 [101dB (A) @ 10ft/3m] |
No. of tones | 32 (UKOOA / PFEER compliant) |
No. of stages | 3 |
Volume control | Max. 110dB (A); Min. 72dB (A) - Tone 2 |
Effective range | 100m/328ft @ 1 KHz |
Voltages DC | 12vdc; 24vdc; 48vdc |
Voltages AC | 115vac; 230vac |
Storage switching | Negative or positive |
Approvals
• 120 candela effective light intensity.
• UV stable PC, field replaceable, color lens filters.
• IECEx KEM 10.0025X
• IEC 60079-0 : 2011
• IEC 60079-1 : 2007-4
• IEC 60079-31 : 2013
• ATEX KEMA 01ATEX2223X
• EN 60079-0 : 2012 + A11
• EN 60079-1 : 2007
• EN 60079-31 : 2014
• TR-CU Ex EAC certificate: RU C-GB.AA71.B.00109
• Inmetro certificate: 16-IEx-0034
Coding
• II 2G Ex d IIB T5 Gb Ta. -50°C to +40°C
• II 2G Ex d IIB T4 Gb Ta. -50°C to +70°C
• II 2D Ex tb IIIC T110°C Db Ta. -50°C to +55°C
• II 2D Ex tb IIIC T125°C Db Ta. -50°C to +70°C
Beacon
Item | Description |
---|---|
Energy | 5 Joules (5Ws) |
Flash rate | 1Hz (60 fpm) |
Peak Candela | 500,000 cd - calculated from energy (J) |
Eff. Intensity | 250 cd - calculated from energy (J) |
Peak Candela | 39,463 cd* - measured ref. to I.E.S. |
Eff. Intensity | 120 cd* - measured ref. to I.E.S. |
Lens colors | Amber, Blue, Clear, Green, Magenta, Red & Yellow |
Tube life | Emissions are reduced to 70% after 8 million flashes |
General
Item | Description |
---|---|
Ingress protection | IP66/67 |
Enclosure material | Marine grade copper free LM6 Aluminum |
Enclosure finish | Chromate & powder coated |
Horn material | High impact UL94 V0 & 5VA FR ABS (Red) |
Cable entries | Dual M20 ISO (one stopping plug incl.) |
Terminals | 0.5 - 2.5mm² (20-14 AWG) |
Enclosure volume | <2 liters |
Line monitoring | Blocking diode included EOL Min. 500 Ohm 2w, or 3k3 Ohm 0.5w resistor or diode (DC versions) can be fitted |
Temperature range | -50° to +70°C (-58°F to +158°F) |
Relative humidity | 90% at 20°C [68°F] |
Weight | 4.80kg/10.56Ibs AC: 5.00kg/11Ibs |