Explosion Proof Strobe Tomar 3150BEP – Wall Mount, 12-74 VDC

SKU: N/A
(1 customer review)

Explosion Proof Strobe Tomar 3150BEP – Wall Mount, 12-74 VDC is Class 1 Division 1 and Class 1 Division 2 hazardous area certified. CSFM Listed and NEMA 4X rated. This explosion proof strobe runs in a 12 – 74VDC voltage. Available in amber, blue, clear, green, and red colors. 2 year warranty on power supply and 1 year warranty on lamp.

Hazardous Area Rating

$1,87198

Price Depends on product option
Make a selection to update price

Shipping Time: 2-10 business days

Need faster options? Contact our Hazardous Areas Experts now for quick alternatives!

Trusted Clients

  • Logo PH66
  • Logo  Exxon
  • Logo Bp
  • Logo Conoco Phillipis
  • Logo Irwing
  • Logo Bayer
  • Logo Tesoro
  • Logo Northen TIer
  • Logo Udelhoven
  • Logo Aloha petroleum
  • Logo Rand
  • Logo Arrow Energy
  • Logo Schlumber
  • Logo Afton
  • Logo Holly frontier
Similar Category:

Explosion Proof Strobe Tomar 3150BEP – Wall Mount, 12-74 VDC

Features:

  • Class 1 Division 1
  • Class 1 Division 2
  • Explosion proof strobe wall mount
  • 3/4” wall mount
  • 12 – 74 VDC
  • Xenon strobe lamp
  • Available in amber, blue, clear, green, and red
  • 2 year warranty on power supply
  • 1 year warranty on lamp
  • CSFM Listed
  • NEMA 4X

Introducing Explosion Proof Strobe Tomar 3150BEP – Wall Mount, 12-74 VDC

The 3150BEP family is designed, tested, and certified for use in hazardous locations and hostile environments classified by the NEC as Class I, Div. 1 & 2, Groups C & D, Class II, Div. 1 & 2, Groups E, F, G, and Class III, Div. 1 & 2. They also meet NEMA standards 3, 4, 4X, 7CD, and 9EFG and are marine rated for use in salt water environments. Design features include housing made of die cast high strength copper-free aluminum alloy with a baked powder epoxy finish, stainless steel hardware, o-ring sealed prestressed glass globe with double pitch acme threads for smooth assembly and ease of maintenance, and an optional guard which need not be removed for relamping. Visual signaling beacon shall be Tomar model number series 3150, 3200, 3300 or approved equal. The light source shall be a field replaceable single-flash xenon strobe lamp. The warning signal must have built-in RFI filters to protect against radio interference and spike voltages. Voltage ranges shall be 12-74VDC, 120VAC, and 240VAC. Beacon must be rated NEMA 4X, with housing made of die cast high-strength copper-free aluminum alloy with baked powder epoxy finish, stainless steel hardware, O-ring sealed pre-stressed globe with double pitch acme threads for smooth assembly and ease of maintenance. Must include a Lexan inner lens and tempered glass outer dome. The housing must be designed to accommodate a dome guard.

Specifications:

ItemDescription
Lamp Type700–R1–COLOR ( please specify lens color )
Flash Rate80 flashes per minute
Light Output200 candela eff.
Voltage and Amperage12–74VDC draws 1.25A @ 12VDC tapering to 0.2A @ 74VDC
850 mA @ 18 VDC; 625 mA @ 24 VDC
170 mA @ 120 VAC; 075 mA @ 240 VAC
Power Supply Output13 watts standard, 11 watts for model 3150
9 joules per flash standard, 8 joules per flash for model 3150
Operating Temperature–40º C to +65º C
Temperature CodeT6 – All voltage and temperature ranges
Size and Weight11.1” tall x 7.44” dia. x 10.6 lbs

3150BEP Models:

ModelDescriptionVoltage
3150BEP–PM3/4” pendant mount12 – 74VDC
3200BEP–PM3/4” pendant mount120VAC
3300BEP–PM3/4” pendant mount240VAC
3150BEP–FM3/4” flange mount12 – 74VDC
3200BEP–FM3/4” flange mount120VAC
3300BEP–FM3/4” flange mount240VAC
3150BEP–WM3/4” wall mount12 – 74VDC
3200BEP–WM3/4” wall mount120VAC
3300BEP–WM3/4” wall mount240VAC

Architect and Engineer Specifications

LED visual signaling beacon shall be Tomar model number series 3024 or 3124 or approved equal. The beacon shall be UL Listed Class I, Division 1, Groups C and D; Class II, Division 1, Groups E, F and G; and Class III for use in specified hazardous locations and /or combustible atmospheres as classified by the National Electric Code.

Operating voltage ranges shall be 10-36 VDC or 85-265 VAC. Operating temperature range shall be from -40 C to 85 C. Beacon shall have built-in selector switch to allow operation in Steady On, Single Flash, or Double Flash modes. Beacon must be rated NEMA 4X, with housing made of die cast high-strength copper-free aluminum alloy with baked powder epoxy finish, stainless steel hardware, O-ring sealed pre-stressed globe with double pitch acme threads for smooth assembly and ease of maintenance. The housing must be designed to accommodate a dome guard.

Explosion Proof Strobe Tomar 3150BEP  – Wall Mount Certifications:

Explosion Proof Strobe Tomar 3150BEP – Wall Mount Other Resources:

MORE OPTIONS FOR YOU:

Reviews & Questions

Share your thoughts!

5 out of 5 stars

1 review

Let us know what you think...

What others are saying

  1. Offshore RigMan88

    Runs All Night And Stays COOL To The Touch!

    Offshore RigMan88

    It’s an explosion proof strobe light. That’s what it does. Smaller than what I expected but the light is really bright.

    Upvote if this was helpful (0) Downvote if this was not helpful (0) Flag for removal

    Something wrong with this post? Thanks for letting us know. If you can point us in the right direction...

×

Login

Continue as a Guest