The APG LPU-2428 Ultrasonic Level Transmitter is designed for highly adjustable measurement in linear and non-linear tanks and channels. It can compute distance, level, flow, and volume internally. The APG LPU-2428 Ultrasonic Level Transmitter is equipped with clever software that enables highly customizable measurement. Distance, level, flow, and volume may all be calculated with the sensor. Additionally, the sensor has a 32-point linearization table for tanks and channels that are not linear. This loop-powered sensor is CSA Class 1, Division 1 certified for usage in hazardous areas. The LPU-2428 takes care of itself thanks to its rugged IP65-rated housing, hazardous rating, and non-contact measurement.
Features:
- ATEX Zone 0 / 2
- Class I Division 1
- Class I Division 2
- IECEx
- Loop powered 4-20 mA output
- Built-in calculations of the current volume, flow, and flow totals
- 32-point linearization table
- -40º – 140ºF (-40º – 60ºC)
- IP65
Specifications:
| Performance | |
| Operating Range | 1 - 25 ft. (0.3 - 7.6 m) on liquids |
| 1 - 10 ft. (0.3 - 3 m) on solids | |
| Beam Pattern: | 9º off axis |
| Internal Temperature Compensation | |
| Frequency: | 69 kHz |
| Accuracy: | ±0.25% of detected range |
| Resolution: | 0.1 in. (2.5 mm) |
| Response Time: | Dependent on output, ranges from 0.6 - 3 seconds |
| Connectivity | |
| Output: | 4-20 mA (loop powered) |
| Loop Resistance: | 600 ohms @ 24 VDC |
| 150 ohms @ 12 VDC | |
| Network/Web with the RST-5000 series module or LOE | |
| Environmental | |
| Ratings: | IP65 |
| Operating Temp: | -40º - 140ºF (-40º - 60ºC) |
| Certification | |
| Class 1, Div. 1, Groups C & D | |
| Class 1, Zone 0, AEx iA IIB, T3; IP65 | |
| Electrical | |
| Total Current Draw: | 4-20 mA |
| Supply Voltage: | 12-28 VDC |
| Wiring Connection: | 2-conductor shielded cable |
| Programming | |
| Interface with RST-4101 USB Module (purchase separately) | The RST-4101 is powered by a USB port connecting the RST to a computer. A 2-conductor terminal strip allows the module to be connected in parallel with the 4-20 mA loop. |
| Volume Measurement Settings: | Formulas for a wide variety of common tank types |
| Flow Measurement Settings: | Formulas for a wide variety of weirs and flumes total flow counter |
| 32-point linearization table for unique tanks, weirs, and flumes | |
| User selected units of measure | |
| Physical | |
| PVDF (Kynar®) transducer housing | |
| PC/PBT upper housing | |
| Transducer Type: Ceramic, PVDF faced |

































What others are saying
There are no contributions yet.