Your cart is empty.

Intrinsically Safe Ethernet Barrier SOLEXY RX13S0200RXN is ATEX Zone 1/21 and Class I Division I, Class II Division I hazardous areas certified. It is backed up with ATEX Apparatus, IECEx apparatus and the USA and Canada Listed Equipment certifications as well
With its high-tech capabilities which include blocking DC signal and providing a very high impedance to low-frequency AC signal, it is one of the best ethernet barriers in the market today. It also features N Female antenna connection suitable for N Male antenna,3/4” npt-m thread connection, stainless steel housing, double connector execution, no coax cable, RP-SMA Female coaxial connector suitable for RP-SMA Male radio connection and ax RF power input 2 Watts (33dBm).
| ATEX Rating | Zone 1 |
| Hazardous Area Rating | Class 1 Division 1 |
| IECEx Certified | Yes |
Introducing the new Intrinsically Safe Ethernet Barrier SOLEXY RX13S0200JXN is designed to be used directly with listed explosion housings or conduit fittings. This coupler is an integrated blocking circuit prevents hazardous energy reaching the antenna if a radio, modem or access point failure occurs. It also allows antenna removal in hazardous areas.
The couplers powerful design allows for the connection to approximately any radio and antenna. It is a highly flexible cost-effective solution to hazardous area radio system deployment. The coupler can also be used as a cable bulkhead.
The Antenna Coupler function is to block DC signal and provide very high impedance to low frequency AC signal.Fitting is approved for hazardous location and can be installed with a simple wrench.
| ATEX certification nr. TÜV CY 18 ATEX 0206158 X |
Ex I M2 (M1) Ex db mb [ia Ma] I Mb II 2 (1) G Ex db mb [ia Ga] IIA/IIB/IIC T5…T6 Gb II 2 (1) D Ex mb tb [ia Da] IIIC T80°C…T100°C Db |
| Standard Ref. | EN 60079-0, EN 60079-1, EN 60079-11, EN 60079-18, EN 60079-31 |
| IECEx certification nr. IECEx MSC 19.0001X |
Ex db mb [ia Ma] I Mb Ex db mb [ia Ga} IIA/IIB/IIC T5….T6 GbEx mb tb [ia Da] IIIC T80°….T100°C Db |
| Standard Ref. | IEC 60079-0, IEC 60079-1, IEC 60079-11, IEC 60079-18, IEC 60079-31 |
| USA & Canada certification cQPSus LR-1504-3 |
Class I, Division 1, GROUP ABCD; Class II, Division 1, GROUP EFG [Ex ia Ga] IIC; [Ex ia Da] IIIC Class I, Zone 1, AEx db mb [ia Ga] IIA/IIB/IIC T6...T5 Gb Zone 21, AEx mb tb [ia Da] IIIC T80°C...100°C Db Ex db mb [ia Ga] IIA/IIB/IIC T6...T5 Gb Ex mb tb [ia Da] IIIC T80°C...T100°C Db |
| Standard Ref. | CAN/CSA C22.2 No. 60079-0 UL 60079-0 CAN/CSA C22.2 No. 60079-1 UL 60079-1 CAN/CSA C22.2 No. 60079-11 UL 60079-11 CAN/CSA C22.2 No. 60079-18 UL 60079-18 CAN/CSA C22.2 No. 60079-31 UL 60079-31 CAN/CSA C22.2 No. 60950-1 UL 60950-1 CAN/CSA C22.2 No. 25-17 UL 1203 CAN/CSA C22.2 No. 30-M1986 CAN/CSA C22.2 No 157 UL 1203 UL 508 CAN/CSA C22.2 No. 94.2-15 UL 508 NEMA 250-2014 |
| Maximum Fault Voltage | 250VDC, 250VAC 50-60Hz |
| Approximate Weight | 0.32 kg (70.6 lb) |
| NEMA rating | Provides a NEMA 4X connection when connected to a NEMA 4X rated enclosure |
| Impedance | 50 Ω |
| Ambient Temperature Range | -40°C (-40°F) to +85°C (+185°F) when max RF input = 2W (T5) (standard) -40°C (-40°F) to +80°C (+176°F) when max RF input = 6W (T5) (optional, consult factory) -40°C (-40°F) to +70°C (+158°F) when max RF input = 2W (T6) (standard) -40°C (-40°F) to +65°C (+149°F) when max RF input = 6W (T6) (optional, consult factory) |
| Approximate Insertion Loss (dB) | ||
| Frequency | J version | R version |
| 100 MHz | 1.3 | - |
| 500 MHz | 0.4 | 1.2 |
| 1.4 GHz | 0.4 | 0.6 |
| 1.7 GHz | 0.5 | 0.6 |
| 2.5 GHz | 0.8 | 0.8 |
| 3.9 GHz | - | 1.1 |
| 4.9 GHz | - | 1.8 |
| 5.4 GHz | - | 1.4 |
| 6.0 GHz | - | 2.0 |