Intrinsically Safe Fitting APG Hammer Union HU1502I-L24-10K-PSIS-E15-K0 Recalibratable Incoloy Pressure Transmitter
Introducing the APG Hammer Union HU1502I-L24-10K-PSIS-E15-K0 Intrinsically Safe Fitting Recalibratable Incoloy Pressure Transmitter: Designed for rugged land-based and offshore drilling, including Mud Logging and Measurement While Drilling. Features Incoloy wetted material compliant with NACE standards for sour gases. Includes a recalibration port for digital adjustments. Holds Class I, Div 1 Intrinsically Safe certification for safe operation in hazardous conditions. Compliant with Class 1, Zone 0 requirements in North America, ATEX in Europe, and IECEx. Approved for use in ATEX Zone 0 and Class I Division 1/2 hazardous areas, certified by IECEx. Offers a 4-20mA output with 0.25% accuracy, standard pressure ranges from 0 to 10,000 psi. Ideal for demanding situations with strong vibration, pressure spikes, and extended temperature compensation.
Features:
- Range 0-10,000 PSIS
- 4-20 mA or 0-5 VDC output
- WECO® 1502 fitting for 2” line
- ±0.25% accuracy of full scale
- Exceptional shock and vibration resistance
- Digital recalibration port
- CSA/ATEX/IECEx Approval
Applications
- Sour gasses
- Oil and gas drilling
- Measurement while drilling
- Cementing
- Mud pumps
- Mud logging
- Fracturing
- Acidizing
- Standpipe
- Stimulation
- Well head measurement
- Choke and kill
- Coiled tubing
Specifications:
| Technical Data | ||
| Performance | Accuracy (linearity, hysteresis, & repeatability): | ±0.25% of full scale (BFSL) |
| Standard Pressure Ranges: | 0-10,000 psis | |
| Overpressure: | Smaller of 1.5 times full scale, or limit of WECO® fitting | |
| Burst Pressure: | 3 times full scale, or limit of WECO® fitting, whichever is smallest | |
| Temp Effects on Zero & Span: | ±0.026% FSO/ºC (±0.01% FSO/ºF) | |
| Life: | 10 million cycles | |
| Frequency Response: | Less than 5mS | |
| Environmental | Operating Temp: | -40 - 85ºC (-40 - 185ºF) |
| Compensated Temp: | -40 - 65ºC (-40 - 150ºF) | |
| Storage Temp: | -50 - 120ºC (-58 - 248ºF) | |
| Enclosure Protection: | IP67/IP65 | |
| Certification | CSA/cCSAus | Contract #237484 |
| IS: | Class I, Division 1; Groups C & D | |
| Class I, Zone 0, AEx ia IIB T4 | ||
| Ex ia IIB T4 | ||
| Ambient: -40 - 85ºC | ||
| ATEX: | 4-20 mA | |
| CE 0344 EX II 1G Ex ia IIB T4 Ga | ||
| (Ta = -40°C to +85°C) | ||
| IECEx: | 4-20 mA | |
| EX ia IIB T4 Ga (Ta= -40°C to +85°C) | ||
| Connectivity | Output Signal @ | 21ºC |
| 4-20 mA: | 3-30 mA max | |
| 0-5 VDC: | 110 mA inrush current | |
| 0-5 VDC: | 3.5 mA operating current | |
| Electrical | Supply Voltage: | 10-28 VDC on sensor |
| Loop Resistance: | 1012 ohms @ 28 VDC decreasing linearly to 0 ohms @ 10 VDC | |
| Insulation Resistance: | >100 megaohms @ 500 VAC, 70ºC | |
| Shunt Cal: | 100% of full scale output | |
| Programming | Recalibration via programming unit | (purchase separately - powered by USB) |
| Physical | Wetted Materials: | Incoloy |
| Conforms to NACE MR-01-75 and ISO 15156-3 standards | ||
| Housing: | 316L Stainless Steel |
Certifications:
- ATEX Declaration
- CSA Certificate
- IECEx Certificate
































What others are saying
There are no contributions yet.