Ion Science Titan 2 Fixed Benzene Gas Monitor

SKU: N/A

The ION Science Titan 2 is a world-leading, hazardous-area certified continuous benzene monitor delivering precise gas speciation down to 0.02 ppm within 60 seconds. Engineered for harsh industrial environments like oil, gas, and chemical plants, it combines ATEX/IECEx zone compliance with a robust, IP65-rated modular design to ensure maximum workforce safety

Weight 33 lbs
ATEX Rating

IECEx Certified

Country of Origin 🇬🇧 United Kingdom (UK)

$18,00000

Price Depends on product option Make a selection to update price
$1800 Import tariffs will be applied

Shipping Time

2 -3 weeks

Need faster options? Contact our Hazardous Areas Experts now for quick alternatives!

Found It Cheaper?

We Match It!
Price Match Guarantee

Need Help?

Speak with a Hazardous Area expert now

Description

ION Science Titan 2 Benzene Monitor

The ION Science Titan 2 is an advanced, wall-mounted continuous benzene monitor. It is designed specifically for safety and compliance in hazardous industrial environments. Moreover, the Ion-science-titan 2-intrinsically-safe-fixed-benzene-detector is engineered to meet the needs of professionals in these demanding settings.

Benzene is a highly toxic carcinogen. Therefore, accurate, continuous detection is vital for protecting site personnel. The Titan 2 offers an unrivaled gas speciation method that eliminates interfering gases like toluene, xylene, and methane. As a result, it provides field professionals with highly accurate real-time readings they can confidently rely on.

Equipped with the innovative MiniPID T2 10.0 eV sensor, the Titan 2 boasts exceptional sensitivity and performance in the field. It can monitor ambient air and sample airborne hazards down to 0.02 ppm (20 ppb) in just 60 seconds.

Additionally, it is equally capable of assessing the performance of vapor recovery units (VRU) up to 20 ppm[cite: 18, 20]. Its internally regulated heating system ensures stable operation even at extreme temperatures. Meanwhile, the user-friendly magnetic switches allow safe menu navigation without opening the housing.

Key Features:

✅ ATEX, IECEx, and QPS Certified for Zone-Rated Hazardous Locationsbr/

✅ Two 3/4 NPT Gland Threads for secure cable entry, plus Dual Magnetic Switches for external menu control

ION Science Titan 2 Technical Specifications:

FeatureDetails
Sensor TypeMiniPID T2 10.0 eV Sensor
Target Gas SelectivityBenzene specific within typical petrochemical matrix
Detectable Range0.02 ppm to 20 ppm
Lower Limit of Detection0.02 ppm (20 ppb) with a 10 ppb resolution
Accuracy±50 ppb or ±10%, whichever is greater (±10 ppb for readings ≤ 0.1 ppm)
Measuring FrequencyOnce per minute (60 seconds)
Flow RateSample flow rate ≥ 100 ml/min
Gas Sample Line Length10 meters maximum length (PTFE, 6 mm OD, 4 mm ID)
DisplayGraphical Black & White LCD (64 x 128 pixels) with backlight;
Bright LEDs for normal operation, faults, and alarms
User InterfaceTwo magnetic switches for non-intrusive menu operation
Temperature StabilityInternally regulated heating for stable operation
Operating TemperatureRecommended range of -20°C to +50°C (-4°F to +122°F)
Humidity Range0% to 99% RH
Ingress ProtectionIP65 rated enclosure against dust and water ingress
Power RequirementsVin (Nominal): 24 V DC @ 3.2 A | Vin (Max): 32 V DC @ 2.4 A
Vin (Min): 19 V DC @ 4.0 A
Communication OutputsIsolated 4-20 mA output;
Isolated RS485 Modbus (ASCII or RTU, simplex/half-duplex or full-duplex);
Micro USB for PC software
Relay OutputsTwo isolated, voltage-free outputs rated at 24 V DC @ 1.25 A
Data StorageOn-board MMC, 2GB capacity (minimum of 6 months data storage)
Cable EntryTwo 3/4 NPT gland threads
Weight and Dimensions15 kg (33 lbs); 219 x 219 x 172 mm (8.6 x 8.6 x 6.8 inches approx.)
Minimum Service Period6 months (PID lamp, electrode stack, inline filter, VRV restrictor,
hydrophobic & carbon filter) | 12 months (adds AirSep filter)

Certifications & Compliance:

🔗 ATEX-Certificate (FTZU 14 ATEX 0172X) – II 2G Ex db IIB+H2 T4 Gb (Tamb. -20°C to +55°C)
🔗 IECEx-Certificate (IECEX FTZU 14.0030X) – Ex db IIB+H2 T4 Gb (Tamb. -20°C to +55°C)
🔗QPS-Certificate (LR1621-1) – Ex db IIB+H2 T4 Gb / AEx db IIB+H2 T4 Gb (Ta = -20°C to +55°C)
🔗 Ingress Protection – IP65 rated dust and water resistance
🔗 Titan 2 brochure V1.0 US

Applications of ION Science Titan 2:

🔹 Oil & Gas
🔹 Chemical Plants
🔹 Bulk Storage Facilities
🔹 Labs & Processing Facilities
🔹 Asphalt Production

What’s in the Box?

📦 1x Titan 2 Benzene Monitor Base Unit (Ex d Enclosure)
📦 1x Removable Service Module Cartridge
📦 1x Integrated Flame Arrestor & Hydrophobic Filter
📦 1x Internal Data Storage MMC Card (2GB)
📦 1x Documentation Kit & Installation Guide

Ordering & Shipping Details

📦 Lead Time: 2 – 3 Weeks
📍 Shipping Terms: Worldwide / Expedited Options
💳 Payment Options: Credit Card, PayPal, Net 30 Terms

FAQs:

What is the detectable range and speed of the Titan 2?
The Titan 2 can accurately detect benzene levels from as low as 0.02 ppm (20 ppb) up to 20 ppm. Furthermore, it does so with a response sampling time of 60 seconds.

How does the monitor handle interfering gases like methane and toluene?
The Titan 2 utilizes a unique separation and sampling method that isolates benzene and eliminates common cross-interfering gases, providing clear, reliable gas speciation.

Can the Titan 2 be serviced without removing the entire device from the site?
Yes. It features an impressive modular design where the main Ex d casing can remain fixed, while the internal components are housed on a remotely serviceable, plug-and-play cartridge module.

Is there an extended warranty available for this instrument?
Yes, registering the monitor online allows you to extend the manufacturer’s warranty for up to 2 years.

Product Accessories

Make Your Job Easy. Try Our Most Popular Accessories

Ion-Science-Titan-Red-Electrode-Stack-ppb-image

Ion Science Titan - Red Electrode Stack (ppb)

SKU: A-846444

The Electrode Stack Sealed PPB (Red) is specifically designed for use within the Ion Science PID sensor for use within Titan benzene-specific monitor . It is capable of detecting benzene to part per billion (ppb) levels.

Brand: Ion Science

In Stock 7-10 business days

$9244

$9.244 Import tariffs will be applied

Ion-Science-Titan-Carbon-Filter-Assembly-with-connectors-main-image

$37800

$37.8 Import tariffs will be applied

Ion-Science-Titan-Hydrophobic-Filter-main-image

Ion Science Titan 2- Hydrophobic Filter

SKU: A-875417

Ion Science Titan 2 - Hydrophobic Filter is used externally to the instrument to stop airborne dirt and debris entering the gas detection system. If the instrument comes into contact with water the filter will allow gas samples through but will stop water entering. This consumable part will become dirty over time and require replacement.

Brand: Ion Science

In Stock 7-10 business days

$5700

$5.7 Import tariffs will be applied

Reviews & Questions

Share your thoughts!

Let us know what you think...

What others are saying

There are no contributions yet.

×

Login

Continue as a Guest