The APG MNU IS Modbus Ultrasonic Level Sensor features a durable design and low power consumption. It is approved for use in ATEX Zone 0 and Class I Division 1 hazardous location. Approved by IECEx. The MNU IS ultrasonic sensors are tough equipment that has an Intrinsically Safe rating for installation in hazardous areas. They include APG’s patented QuickMode technology for energy-efficient, on-demand measurements, as well as optional GDT surge protection. All MNU IS sensors are fully programmable via RS-485 Modbus connections, as well as through the use of APG Modbus software and an RS485-to-USB converter.
Features:
- ATEX Zone 0
- Class I Division I
- IECEX
- Modbus Flexibility Meets High-Performance Ultrasonic
- Rugged
- Low-power
- rated Intrinsically Safe for hazardous location
- Internal Temperature Compensation
- 2” NPT and 3/4” NPT mounting options
- QuickMode ready-to-read in as little as 250 ms
- Optional Gas Discharge Tube surge protection
- Ranges: 1 ft – 25 ft, 5 in – 12 ft
- Self-Contained Sensor
- Multiple Housing Options
- RS-485 Modbus RTU Interface
- Measure Distance, Level, or Volume
- IP68
Versions:
MNU-IS-6424-C6A
- Range: 1 – 25 FT, 6 FT cable
MNU-IS-6424-C6C
- Range: 1 – 25 FT, 6 FT cable
MNU-IS-8424-C6A
- Range: 5 – 144 Inches, 6 FT cable, cable gland with spiral strain relief
MNU-IS-2424-C6A
- Range: 1-25 FT, 2″ NPT, 6 ft cable, cable gland Atex
MNU-IS-6425-C6A
- Range: 1-25 FT, 2″ NPT, 6 ft cable, w/gas discharge tube surge protection
New QuickMode
- Get an on-demand measurement in as little as 250 ms.
Easy Wiring and Set-up
- Everything about MNU IS setup is easy, from simple daisy chain wiring to remote configuration via the Internet.
Applications
- Class I Division 1 Hazardous Locations
- Water/Wastewater
- Sewer/Lift Stations
- Low-power Remote Locations
Specifications:
Performance | |
Frequency/Operating Range: | |
69 kHz: | 1 - 25 ft (0.30 - 7.62 m) |
81 kHz: | 5” - 12 ft (0.13 - 3.66 m) |
Beam Pattern: | 9º off axis |
Internal Temperature Compensation | |
Accuracy: | ±0.25% of detected range |
Resolution: | 0.1 in. (2.5 mm) |
Response Time: | Programmable |
Connectivity | |
Output: | Modbus RTU (RS-485) |
Online Access/Control | Via APG’s Tank Cloud & RST-5003 or LOE contoller |
Environmental | |
IP68 (3 meters submerged for 48 hours) | M12 connector only rated IP67 |
Operating Temp: | |
Standard: | -30º - 60ºC (-22º - 140ºF) |
Alternate: | -20º - 50ºC (-4º - 122ºF) |
Programming | |
Interface with RS-485 Modbus RTU | APG Modbus Windows-compatible software can be provided to adjust internal parameters. |
User selected Units of Measure, Response Rate, Volume Calculations, and more. | |
Electrical | |
Supply Voltage: | 8 - 24 VDC |
Operating Current Draw: | 18 - 26 mA @ 24 VDC, Typical 18 mA |
32 - 63 mA @ 8 VDC, Typical 37 mA | |
Waiting Status Current Draw: | 13 mA @ 24 VDC |
17 mA @ 8 VDC | |
Wiring Connection: | 4-conductor shielded, twisted-pair cable |
Gas Discharge Tube Surge Protection 150 V, 1 kA | |
Physical | |
Upper Housing: | PC/PBT blend |
Transducer Face: | PVDF |
Certification | |
CSA/cCSAus Contract #237484 | Intrinsically Safe |
Class I, Div. 1, Groups C & D, T4 | |
Class I, Zone 0, AEx ia IIB T4 Ga | |
Ex ia IIB T4 Ga | |
ATEX | II 1G Ex ia IIB T4 Ga |
IECEx | Ex ia IIB T4 Ga |
CE |
What others are saying