In industries like oil and gas, chemical processing, pharmaceuticals, and utilities, the risk of explosions from flammable gases, dust, or fibers is a constant concern. Equipment used in these hazardous environments must meet strict safety standards, especially when it comes to electrical and electronic devices. That’s where intrinsic safety comes in—a preventative approach that limits energy so it cannot ignite hazardous atmospheres, even during a fault.
The 2025 landscape for intrinsically safe regulations USA continues to evolve, influenced by updates to UL standards, NEC codes, and increasing global harmonization with IEC standards. For safety managers, compliance officers, and facility engineers, understanding these regulatory frameworks is not just about ticking boxes—it’s about protecting lives, property, and operations.
In this comprehensive guide, we break down U.S.-specific intrinsic safety regulations, compare them to international standards, and provide practical tools—including tables, product recommendations, and best practices—to help you stay compliant.
Explore our full range of intrinsically safe devices for every zone classification → Shop Certified Gear
What Are Hazardous Locations Under U.S. Regulations?
Hazardous locations are defined by the potential presence of flammable gases, vapors, combustible dust, or ignitable fibers.
Hazardous Location Classifications (NEC 500)
Class | Type of Hazard | Example Industries |
---|---|---|
Class I | Flammable gases and vapors | Oil refineries, chemical plants |
Class II | Combustible dusts | Grain silos, sugar processing |
Class III | Ignitable fibers/flyings | Textile mills, woodworking facilities |
Each class is broken down further by Division:
Division 1: Hazard present under normal conditions
Division 2: Hazard present under abnormal conditions
This classification system guides how equipment must be rated and where it can be safely used.
Need help choosing equipment for your Class I or Zone 1 area? → Talk to a Compliance Expert

How Do NEC Class/Division and Zone Systems Compare?
The U.S. follows two systems for classifying hazardous areas:
NEC 500 (Class/Division)
NEC 505 (Zones), which aligns with IEC/ATEX systems
Comparison Table: NEC 500 vs NEC 505
NEC 500 (Class/Division) | NEC 505 (Zones) | Hazard Frequency | Equivalent Hazard |
---|---|---|---|
Class I, Division 1 | Zone 0 / Zone 1 | Continuous / Intermittent | Flammable gases/vapors |
Class I, Division 2 | Zone 2 | Abnormal | Flammable gases/vapors |
Class II / III | N/A | U.S.-only system | Dust and fibers |
While NEC 500 remains the dominant classification in the U.S., NEC 505 is increasingly adopted in globally integrated operations to simplify product compliance and reduce cost.
What UL Standards Govern Intrinsic Safety?
The U.S. uses standards published by Underwriters Laboratories (UL) to test and certify intrinsically safe equipment.
Key UL Standards for Intrinsic Safety
UL 913: Establishes requirements for IS equipment used in Class I, II, III Divisions
UL 60079-11: Aligns with international standard IEC 60079-11 for IS equipment in Zones
UL 121201: Applies to associated apparatus used outside the hazardous area
UL vs IECEx/ATEX Standards
UL Standard | Region | Equipment Type | Harmonized With |
---|---|---|---|
UL 913 | U.S. | IS Equipment (Class/Div) | No |
UL 60079-11 | U.S./Global | IS Equipment (Zones) | IECEx, ATEX |
UL 121201 | U.S. | Associated Apparatus | IEC 60079-25 |
Always check the equipment label for UL markings and hazardous location compatibility. Devices may also carry dual certifications for both Class/Div and Zone systems.
What Is Intrinsically Safe Apparatus vs Associated Apparatus?
Understanding the distinction between these two is key to safe IS system design.
Intrinsically Safe Apparatus: Located within the hazardous area, designed to operate with limited voltage and current to prevent ignition. Examples include sensors, handheld radios, smartphones.
Associated Apparatus: Installed in non-hazardous areas, these devices interact with IS apparatus and control power levels through barriers or isolation techniques. Common examples include zener barriers, isolators, and signal conditioners.
Together, they must be certified under the entity concept, ensuring that the system as a whole meets safety standards.
Get field-ready devices for both hazardous and safe areas → View Radios & Sensors
How Are Intrinsically Safe Circuits Designed and Wired?
IS circuits follow strict design protocols to limit energy transfer and eliminate spark risk. Key elements include:
1. Energy Limitation
Maximum voltage and current are strictly regulated (e.g., 30V and 100mA typical thresholds)
2. Barriers and Isolators
Zener barriers are the most common and inexpensive
Galvanic isolators offer better performance and ease of maintenance
3. Control Drawings
Provided by the manufacturer
Must be followed precisely during installation
Detail permissible cable types, lengths, and connections
Failing to comply with wiring and entity parameters voids the intrinsic safety of the entire circuit.
How to Verify Compliance of Field Devices?
Use this checklist to ensure a device is compliant with intrinsically safe regulations in the USA:
UL Marking: Must include standard used (UL 913 or UL 60079-11)
Area Classification: Clearly marked Class/Div or Zone ratings
Temperature Code: e.g., T4, T5
Control Drawing: Mandatory for installation reference
Gas Group Rating: Group A (Acetylene), B (Hydrogen), C (Ethylene), D (Propane), etc.
Inspection Certificate: From UL or equivalent nationally recognized testing lab (NRTL)
Best Practices for Implementing Intrinsic Safety
Compliance goes beyond equipment—it’s about maintenance, training, and documentation. Follow these best practices:
Routine Audits
Inspect IS equipment and barriers every 6–12 months. Look for wear, corrosion, or unauthorized modifications.
Training Programs
Train electricians, engineers, and supervisors on:
Class/Div and Zone systems
Reading control drawings
Proper wiring techniques
Documentation Management
Maintain up-to-date records:
Control drawings
Inspection logs
Certification documents
Maintenance histories
Simplify your inspections with rugged IS tablets for real-time logs → Explore Rugged Tablets
Redundancy in Design
Design systems with fault-tolerant features—such as dual barriers—for critical operations.
Top Intrinsically Safe Devices for 2025
Choose only certified and field-proven IS devices. Below are highly rated products from Intrinsically Safe Store:
Product | Certification | Features | Use Case | Product Type |
---|---|---|---|---|
Rugged EDGEOne IoT Hub Smartphone | ATEX / IECEx | Android OS, LTE, rugged housing | Field communication, mobile data logging | Intrinsically Safe Smartphone |
Atexxo Intrinsically Safe iPad Pro 11″ | ATEX Zone 2 | Full iOS experience, Wi-Fi & LTE | Data entry, mobile apps, SCADA | Intrinsically Safe Tablet |
CorDEX ToughPIX Extreme TP3Ex Camera | ATEX / IECEx / UL | 5MP stills, HD video, flash | Hazardous area photo/video documentation | Intrinsically Safe Camera |
ION Science Tiger Select Benzene Detector | UL / ATEX / IECEx | Benzene-specific PID detection | VOC monitoring, personal safety | Intrinsically Safe Gas Detector |
Best Product by Use Case
Mobile Workers (Oil & Gas): Ecom Smart-Ex 02
Hazard Area Photography: CorDEX ToughPIX II
Tablet for Field Data Collection: Bartec Agile X IS
Entry-Level Rugged Device: UNIWA W888
Ensure compliance and protect your team—Shop safety-certified gear now → Start Here
FAQs About Intrinsically Safe Regulations USA
What’s the difference between explosion-proof and intrinsically safe?
Explosion-proof enclosures contain potential explosions, while intrinsically safe devices prevent ignition entirely by limiting available energy.
Can ATEX devices be used in the U.S.?
Only if they also carry UL or FM (Factory Mutual) certification. ATEX alone is not accepted for U.S. regulatory compliance.
Are intrinsically safe devices mandatory for Class I Div 2?
Not always, but using IS devices reduces cost and inspection requirements versus explosion-proof gear.
What’s a control drawing?
A manufacturer-supplied wiring schematic detailing how an IS device must be installed. Following it is legally required under U.S. code.
How often should barriers and IS equipment be tested?
Industry best practice is every 6–12 months, or sooner if devices are exposed to vibration, moisture, or tampering.
Conclusion: Why Understanding Intrinsically Safe Regulations Matters
Navigating intrinsically safe regulations USA in 2025 is critical for anyone working in hazardous industries. From selecting the right UL-certified products to following control drawings and maintaining inspection logs, every step matters.
When your workers operate equipment in volatile environments, even small mistakes can lead to catastrophic consequences. That’s why using intrinsically safe equipment that complies with NEC 500/505 and UL913 is essential—not only for OSHA compliance, but also for workforce safety and business continuity.