E+E Elektronik HTS201 Room Sensor for Relative Humidity and Temperature

SKU: HTS201-M1A6RG2SBL-5VN0SBH55

The E+E Elektronik HTS201: Accurate RH and T measurement. Patented sensor tech for reliability. Analog or RS485 interface options. Easy install, tool-free maintenance. Configurable via PC. Available in US/EU formats, with/without display.

 

ATEX Rating

IECEx Certified

$25846

Shipping Time: 15-20 business days

Need faster options? Contact our Hazardous Areas Experts now for quick alternatives!

Trusted Clients

  • Logo PH66
  • Logo  Exxon
  • Logo Bp
  • Logo Conoco Phillipis
  • Logo Irwing
  • Logo Bayer
  • Logo Tesoro
  • Logo Northen TIer
  • Logo Udelhoven
  • Logo Aloha petroleum
  • Logo Rand
  • Logo Arrow Energy
  • Logo Schlumber
  • Logo Afton
  • Logo Holly frontier
Similar Category:

E+E Elektronik HTS201 Room Sensor for Relative Humidity and Temperature

Hazardous location E+E Elektronik HTS201 Room Sensor for Relative Humidity and Temperature delivers precise and reliable measurements of relative humidity (RH) and temperature (T) in residential and commercial building automation. Its patented sensor technology ensures outstanding measurement performance, resilient even in dusty environments. The innovative enclosure prevents false air ingress and minimizes self-heating.

This device provides RH and T data through two analog outputs or via the digital RS485 interface supporting Modbus RTU or BACnet MS/TP protocols. Additionally, it offers dewpoint temperature (Td) data through Modbus RTU and BACnet MS/TP.

Featuring a functional design, the elegant enclosure adheres to regional standards and offers an optional display. Its construction simplifies installation, with a back cover housing push-in spring terminals separately from the electronics in the front cover. This allows easy commissioning by attaching the active part just before use and facilitates swift, tool-free replacement of the active component.

Configuration is streamlined for the digital version via PC, using the free PCS10 Product Configuration Software and an optional configuration adapter.

HTS201 is available in both US and EU formats, with or without a display, catering to different preferences and requirements.

Features:

Measurement Performance:

  • High RH/T Accuracy: Ensures precision in measurements.
  • Excellent Long-Term Stability: Consistent performance over time.
  • State-of-the-Art E+E RH/T Sensing Element: Utilizes advanced technology for accuracy.
  • Protected by E+E Proprietary Coating: Shields the sensor for extended lifespan.
  • Patented Sensor Technology: Innovative technology for superior performance.

Enclosure and Connection:

  • Innovative Design Avoids False Air Ingress: Prevents inaccurate readings.
  • Time-Saving Installation and Wiring: Quick and efficient setup.
  • Snap-On Without Tools: Easy assembly and maintenance.
  • Push-In Spring Terminals: Simplifies connections.
  • All Electronics Inside Front Cover: Ensures protection and convenience.
  • Smooth Cover Surface: Repels dust and eases cleaning.
  • Dust Repellent and Easy Cleaning: Maintains optimal functionality.
  • EU and US Format: Available in regional standards.
  • UL94HB Approved Enclosure Material: Ensures safety standards compliance.

Outputs:

  • Two Analog Outputs: Provides 0-10V and 4-20mA options.
  • RS485 Interface with Modbus RTU and BACnet MS/TP: Digital interface for data transmission.
  • Large Graphic Display: Offers clear visual data representation.

Inspection Certificate:

  • According to DIN EN 10204-3.1: Ensures compliance with inspection standards.
  • Available via E+E Certificate Service: Accessible documentation for validation.

Protective Sensor Coating: The proprietary coating extends sensor lifespan, ensuring optimal performance in corrosive environments like offshore applications. It also enhances long-term stability in dusty, dirty, or oily conditions by preventing impedance caused by deposits on the sensor surface.

 

Specifications:

Technical Data
Measurands
Relative Humidity (RH)
Measuring range0...100 %RH, non-condensing
Accuracy1 incl. hysteresis, non-linearity and repeatability
0...100 %RH
±(2 + 0.003 * mv) %RH mv = measured value
Temperature dependency of electronics, typ0.008 % RH / °C (0.004 %RH / °F)
Factory calibration uncertainty2) @ 23 °C (73 °F)
0...90 %RH±(0.7 + 0.003 * mv) %RH mv = measured value
>90...100 %RH±1 %RH
1) Defined against E+E calibration reference at 23 °C (73 °F). With supply voltage 24 V DC, 0.2 m/s (39. 4 ft/min) medium flow and load resistor 250 Ω for version with current output.
2) Defined at with an enhancement factor k=2, corresponding to a confidence level of 95 %.
Temperature (T)
Measuring range-30...+60 °C (-22...+140 °F)
Accuracy1
0- 10 V, RS485±0,25 °C (±0.14 °F)
4 - 20 mA (2-wire)±0,38 °C (±0.21 °F)
Temperature dependency of electronics, typ.0.006 K/K
Factory calibration uncertainty2) @ 23 °C (73 °F)±0.1 °C (±0.056 °F)
1) Defined @ 23 °C (73 °F) against E+E calibration reference. With supply voltage 24 V DC, 0.2 m/s (39. 4 ft/min) medium flow and load resistor 250 Ω for version with current output.
2) Defined with an enhancement factor k=2, corresponding to a confidence level of 95 %.
Calculated Physical Quantity
fromup tounit
Dew point temperature Td-30 (-22)60 (140)°C (°F)
Outputs
Analogue
T: acc. to ordering guide0 - 10 V-1 mA < IL < 1 mAIL = load current
RH: 0...100 %4 - 20 mA (2-wire)RL < (V+ - 10) / 0.02 < 500 ΩRL = load resistance
Digital
Digital interfaceRS485 (HTS201 = 1 unit load)
ProtocolModbus RTU
Factory settingsBaud rate according to ordering guide, 8 data bits, parity even, 1 stop bit, Modbus address 45
Supported Baud rates9 600, 19 200 and 38 400
Measured data typeFLOAT32 and INT16
ProtocolBACnet MS/TP
Factory settingsBACnet address 45
Supported Baud rates9 600, 19 200, 38 400, 57 600, 76 800 and 115 200
1) Ex works: see ordering guide
General
Power supply class III USA & Canada: Class 2 supply necessary, max. voltage 30 V DC
0 - 10 V, RS48515 - 35 V DC or 24 V AC ±20 %
4 - 20 mA (2-wire)10 + 0.02 x RL < V+ < 35 V DC (RL < 500 Ω)RL = load resistance
Current consumption, typ@ 24 V DC@ 24 V AC
0 - 10 V6 mA14 mArms
4 - 20 mAAcc. to output currentAcc. to output current
RS4855 mA12 mArms
Electrical connectionPush-in spring terminals max. 1.5 mm2 (AWG 16)
Display1.8" LCD, dot-matrix, 2 lines, visible area 38 x 31 mm (1.5" x 1.2")
Humidity range
Operation0…100 %RH non-condensing
Storage0…95 %RH non-condensing
Temperature range, operation and storage
without display-30...+60 °C (-22...+140 °F)
with display -20...+60 °C (-4...+140 °F)
Enclosure
MaterialPC (Polycarbonate), RAL 9003 (signal white), UL94 HB approved
Protection ratingIP30
Electromagnetic compatibilityEN 61326-1EN 61326-2-3Industrial environment
FCC Part15 Class BICES-003 Class B
Shock and vibrationTested according to EN 60068-2-64 and EN 60068-2-27
ConformityCE & UKCA
ConfigurationPCS10 Product Configuration Software (free download) and optional configuration adapter

E+E Elektronik HTS201 Room Sensor for Relative Humidity and Temperature

Certifications:

Resources:

Reviews & Questions

Share your thoughts!

Let us know what you think...

What others are saying

There are no contributions yet.

×

Login